CC-Link IE TSN configuration

1.4
CC-Link IE TSN configuration
Procedure
 Before communication
1
Connect each unit with an Ethernet cable. (Refer to
2
Set the station number using the rotary switches on the CC-Link IE TSN communication circuit
board. (Refer to
3
Clear all parameters, then turn the inverter power OFF and ON again.
 Registering a profile
1
Start GX Works3.
2
On the menu bar, select [Tool] → [Profile Management] → [Register...].
3
Select a CSP+ file to be registered on the "Register Profile" screen, and click the [Register]
button.
NOTE
• A profile is a compressed file (such as *.zip, *.ipar, and *.cspp). Register a profile without decompressing the file.
 Creating a project file
1
For information on creating and opening a project, go to [Help] → [GX Works3 Help].
 Detecting an Inverter
1
In the "Navigation" window, select [Parameter] → [Module Information] then select the module
name.
8
INTRODUCTION
page
20.)
Example: 1 (H01)
page
4.)