Spraying Setup - Graco Reactor A-20 Operation

Air operated, electrically heated plural component proportioner
Hide thumbs Also See for Reactor A-20:
Table of Contents

Advertisement

Spraying Setup

Spraying Setup
1. After reaching spray temperatures, engage gun
piston safety lock.
2. Close gun fluid manifold valves A and B.
ti2728a
3. Attach gun fluid manifold. Connect gun air line.
Open air line valve.
4. Set PRESSURE RELIEF/SPRAY valves (SA, SB) to
SPRAY.
SA
26
ti2409a
ti2543a
SB
ti8442a
5. Open air inlet ball valve (DD).
S
DD
6. Turn both air regulators (AU, AS, page 12)
counterclockwise to 0 pressure.
7. Turn RUN/PARK switch to RUN.
8. Turn Pump Mode Function knob to START.
9. Slowly increase each UP/DN air regulator setting by
alternating pattern 5-10 psi (0.035-0.07 MPa,
0.35-0.7 bar) at a time until the approximate stall
(static) pressure is achieved on fluid gauges (GA)
and (GB). Leave UP stroke regulator setting at
approximately 10 psi (0.07MPa, 0.7 bar) lower than
DN stroke.
GA
10. Open gun fluid manifold valves A and B.
ti2414a
ti8449a
GB
ti8441a
311511G

Advertisement

Table of Contents
loading

This manual is also suitable for:

253831

Table of Contents