Maintenance - Graco Reactor A-20 Operation

Air operated, electrically heated plural component proportioner
Hide thumbs Also See for Reactor A-20:
Table of Contents

Advertisement

Maintenance

Check and add TSL to B side pump wet-cup daily.
Check ISO lube bottle for significant discoloration or
crystallization daily. Replace with fresh TSL when
needed.
Ensure ISO (A) pump is down and in PARK position
during every shutdown.
Keep any ISO (A) fluid from being exposed to atmo-
sphere to prevent crystallization.
Remove inlet filter screen plug (V, Y) and clean
screens if increased unbalanced pressures between
A and B is noticed or as needed for fluids used. Also
clean after flushing.
Close gun fluid shutoff valves when not in use.
If using a Fusion Air Purge gun, add grease with
grease gun per manual.
Clean gun filter screens and mix chamber ports reg-
ularly, or when increased unbalanced pressures
between A and B is noticed. See gun manual.
Use lithium grease or Iso Pump Oil on all threaded
fluid fittings on the "A" side.
311511G