Using the menus (Continued)

Displaying Information (Status display)

This displays information about the input signal, lamp use time, etc.
Item
Description
Input
Input source name
[Note 1]
Mode name
RGB input mode
Resolution
Resolution (in dots)
Frequency
Sync frequency
[Note ]
Sync
Sync signal polarity
Signal format
Y/P
/P
signal format
B
R
Video mode
Color method of video signal
[Note ]
Lamp time
Time of lamp use
Lamp reset count
The count for lamp replacement
Total time
The total time that this projector is
used.
[Note 4]
Version
Firmware version
Notes
1:
The mode of supported RGB signals
:
Sync signal polarity shown as P (positive) or N (negative) for [H/V].
:
Displays [Lamp time] as a measure of when the lamp should be replaced. (Cannot be
used as a counter of guaranteed lamp time.) Please replace the lamp after 000 hours
of use if [Lamp power] is set to [Standard], or after 000 hours of use if [Lamp power]
is set to [Low], consult with a dealer about getting replacement for lamp TLPLW1 (sold
separately).
4:
[Version] shows the version of the projector's internal control program. This version will
be requested for customer service purposes.
Note
The displayed information will not be refreshed if the status changes. To refresh the
information, dismiss the display, then display it again.
"Yes": displayed, "No": not displayed
Computer
Y/P
/P
Video
B
R
Yes
Yes
Yes
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
No
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
p.53
is shown.
4

About lamp

The product's light source is a mercury lamp that lights at increased internal pressure. Be
sure to fully understand the following characteristics of the lamp and handle it with extreme
care.
The lamp may burst with a loud noise due to impact or deterioration, or fail to light at the
S-video
expiration of its life.
Yes
How long it takes before the lamp bursts or the life expires may vary greatly by lamp.
No
Some may burst shortly after first use.
No
Burst is likely to happen if the lamp is used after the replacement period has elapsed.
No
When the lamp bursts, the broken pieces of glass may get inside the product or be
No
released outside from the openings for ventilation.
When the lamp bursts, a slight amount of mercury gas enclosed in the lamp along with
No
glass dust may be released from the openings for ventilation.
Yes
Yes
Immediately replace the lamp when a replacement message
Yes
appears on the screen.
Yes
When the replacement time approaches, a message will appear on the screen.
The risk of burst will increase if the lamp is continuously used without being replaced.
Yes
Frequently check the used hours and prepare spares when the replacement time
approaches. (Refer to "Status display".
When the lamp is broken
If glass components, including a lamp and a lens, should break, handle the broken
pieces with care to avoid injury and contact your dealer for repair service.
In the event of lamp burst, unplug the product from the wall outlet, leave and completely
ventilate the room. Then, thoroughly clean the area around the projector and discard
any edible items placed in that area, as they may be contaminated.
If the lamp bursts, consult a doctor if glass dust or mercury gas gets into your eyes or is