<3> Functions available to each user
The available functions of the Integrated Centralized Control Web vary depending on the user who logs in to the browser.
Function
Floor layout
Show groups
HWHP
Chiller
Monitor/
operation
MEHITS CH & HP
Measurement
Status
AHC Status
Advanced
Energy Use Status
Energy
management list
Energy
management
Ranking
*2
Target Value
*3
Peak-Cut
Schedule settings
Schedule
Date range setting
Error List
Notice
Unit error log/
Communication
error log
Filter sign
Screen display
settings
User registration
Settings
Date and Time
Settings
License
Registration
Send Mail Log
Outdoor Unit Status
Free Contact
Maintenance
Gas Refrigerant
Amount Check
Reset Emergency
Stop
*5
CSV Output
*1: The table can be displayed only when the "Charge" license has been registered.
*2: The target values cannot be set on the Integrated Centralized Control Web.
*3: The data can be displayed only when "Energy Management License Pack" has been registered.
*4: The tenant management users cannot set the weekly schedule for each season.
*5: The data can be output in CSV format only on PCs. The data cannot be output in CSV format on tablet terminals.
*6: Chiller units, MEHITS CH & HP and HWHP units cannot be monitored or operated on the smartphone.
The operating state of the air conditioners is displayed on the
floor layout.
The operating state of the air conditioners is displayed on the list
screen.
The operating state of HWHP is displayed on the list screen.
The operating state of chiller is displayed on the list screen.
The operating state of MEHITS CH & HP is displayed on the list
screen.
The temperature/humidity data and electric energy data are
displayed.
The input/output status of Advanced HVAC CONTROLLERs can
be displayed.
The air conditioners can be operated.
The power consumption, outdoor temperature and operation
time can be displayed in bar graphs or line graphs for
comparison.
The results of apportionment of energy consumption to energy
management blocks, meters, indoor units and outdoor units are
*1
displayed.
The air conditioners are displayed in descending order of power
consumption or fan operation time.
The target values of power consumption in one year, in each
month and in each block can be checked.
The peak-cut control level and average electric power are
displayed.
Note: "Energy Management License Pack" is required.
It is possible to set the weekly schedule based on the day-of-the-
week pattern (for each season), annual schedule and daily
*4
schedule for the units in each group, in each block or on each
floor or all units collectively.
The periods for weekly schedules 1 to 5 can be set.
The addresses of units in trouble and error codes and the
addresses of units whose troubles have been detected are
displayed.
128 errors which have occurred in each set of AE-200/AE-50/
EW-50 are displayed. (64 unit errors and 64 communication
errors)
A list of units on which the filter sign is on is displayed.
The items related to screen display can be set.
The building manager, tenant manager and general users can
be set.
The current date and time can be set.
Licenses can be registered in each set of AE-200/AE-50/EW-50.
The history of transmission of error notification e-mails can be
displayed in list form.
The capacity values, high pressure values and low pressure
values of the outdoor units can be checked.
The input/output state of the indoor unit free contacts can be
checked.
The coolant quantity of the outdoor unit can be inspected.
Emergency stop can be canceled.
The apportionment parameters, power consumption and energy
management data can be output in CSV format.
Details
22
Building
Tenant
General user
manager
manager
*6
*6
*6
*6