Install Air Fittings; Ground System - Graco 26C624 Instructions Manual

Automatic airless spray guns
Table of Contents

Advertisement

Installation

Install Air Fittings

1. Install 1/4 in. tube fitting into the cylinder (CYL) air
port.
2. Manifolds 241161 and 241162: Install plugs into
the atomization (ATOM) air port and the fan (FAN)
air port.
F
. 2: Air Fittings
IG

Ground System

The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
The following grounding instructions are minimum
requirements for a system. Your system may include
other equipment or objects that must be grounded.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment. Your
system must be connected to a true earth ground.
6
CYL
ATOM
TI8225a
FAN
Ground Pump
Ground the pump by connecting a ground wire and
clamp between the fluid supply and a true earth ground
as instructed in your separate pump instruction manual.
Ground Air Compressors and Hydraulic
Power Supplies
Ground them according to the manufacturer
recommendations.
Ground Air, Fluid, and Hydraulic Hoses
Connected to Pump
Use only electrically conductive hoses with a maximum
of 100 ft (30.5 m) combined hose length to ensure
grounding continuity. Check the electrical resistance of
your air and fluid hoses at least once a week. If the total
resistance to ground exceeds 25 megohms, replace the
hose immediately.
NOTE: Use a meter that is capable of measuring
resistance at this level.
Ground Spray Gun
Ground the spray gun by connecting it to a properly
grounded fluid hose and pump.
Ground Fluid Supply Container
Ground the fluid supply container according to local
code.
Ground Object Being Sprayed
Ground the object being sprayed according to local
code.
Ground Solvent Pails
Ground all solvent pails that are used with flushing
according to local code. Use only metal pails, which are
conductive. Do not place the pail on a non-conductive
surface, such as paper or cardboard, which interrupts
the grounding continuity.
311053L

Advertisement

Table of Contents
loading

This manual is also suitable for:

28804828855426c265

Table of Contents