TABLE 33 – ISN TRANSMITTED DATA (CONT'D)
ISN
CHARACTER
PAGE
P38
110
P39
111
P40
112
P41
113
P42
114
P43
115
P44
116
P45
117
P46
118
P47
119
P48
120
P49
121
P50
122
P51
123
P52
124
P53
125
P54
126
P55
127
P56
128
P57
129
P58
130
P59
131
*
The operational and fault codes sent to ISN pages 56 through 59 are defined in Table 35. Note that this table of fault and operational codes
is for all DX products.
JOHNSON CONTROLS
ISN CONTROL (CON'T)
TYPE
DATA
Evaporator Heater
Digital
Status
Evaporator Pump
Digital
Status
SYS 1
Digital
Comp. 2 Run
SYS 2
Digital
Comp. 2 Run
SYS 1 Liquid Line
Digital
Solenoid Valve or
EEV Pilot Solenoid
SYS 1 Hot Gas
Digital
Bypass Valve
SYS 1
Digital
Comp. 2 Run
SYS 2
Digital
Comp. 2 Run
SYS 2 Liquid Line
Digital
Solenoid Valve or
EEV Pilot Solenoid
Lead System
Digital
(0=SYS 1, 1=SYS 2)
SYS 1
Digital
Comp.3 Run
SYS 2
Digital
Comp. 3 Run
Chilled Liquid Type
Digital
(0=Water, 1=Glycol)
Ambient Control Mode
Digital
(0=Std. Ambient,
1=Low Ambient)
Local/Remote
Control Mode
Digital
(0=Local,
1=Remote)
Units
Digital
(0=Imperial, 1= SI)
Lead/Lag Control
Digital
Mode
(0=Manual,1= Remote)
Digital
----
* SYS 1
Coded
Operational Code
* SYS 1
Coded
Fault Code
* SYS 2
Coded
Operational Code
* SYS 2
Coded
Fault Code
SECTION 10 – MAINTENANCE
ISN
CHARACTER
TYPE
PAGE
P60
132
Coded
P61
133
Coded
P62
134
Coded
P63
135
Coded
P64
136
Coded
P65
137
Coded
P66
138-141
Analog
P67
142-145
Analog
P68
146-149
Analog
P69
150-153
Analog
P70
154-157
Analog
P71
158-161
Analog
P72
162-165
Analog
P73
166-169
Analog
P74
170-173
Analog
P75
174-177
Analog
P76
178-181
Analog
P77
182-185
Analog
P78
186-189
Analog
P79
190-193
Analog
P80
194
Digital
P81
195
Digital
P82
196
Digital
P83
197
Digital
P84
198
Digital
DATA
----
SYS 1 Condenser
Fan Stage
----
SYS 2 Condenser
Fan Stage
----
Unit Control Mode
(0=Leaving Water,
1=Return Water,
2=Discharge Air,
3=Suction Press.,
4=Cooling
5=Heating)
Anti-Recycle Timer
Leaving Chilled Liquid
Temp. Cutout
Low Ambient
Temp. Cutout
----
Low Suction
Pressure Cutout
High Discharge
Pressure Cutout
Setpoint
Cooling Range
----
----
SYS 1 Discharge
Temp.
(EEV Only-Optional)
SYS 1 Discharge
10
Superheat
(EEV Only- Optional)
SYS 2 Discharge
Temp.
(EEV Only- Optional)
SYS 2 Discharge
Superheat
(EEV Only- Optional)
----
----
----
----
----
149

Advertisement

Table of Contents
loading

Table of Contents