5 5

Frequently Asked Questions and Troubleshooting

A. Frequently Asked Questions
ISSUE
Condensation on the glass
Blue flames
Erratic flames
Odor from fireplace
Film on the glass
Metallic noise
Is it normal to see the pilot flame burn
continually?
Power Outages
(battery backup)
Wall above appliance feels hot to
the touch.
Contact your dealer for additional information regarding operation and troubleshooting. Visit www.heatilator.com to
locate a dealer.
18
Heatilator • NBV30-IFT, NBV33-IFT, NBV36-IFT, NBV42-IFT Owner's Manual • 2624-981 Rev. C • 8/20
This is a result of gas combustion and temperature variations. Prior to appliance being turned
on, the inside of the glass has cooled below the dew point producing a byproduct of combus-
tion: water in the form of condensation. As the fireplace glass warms, the condensation will
disappear.
In the summer, the inside of your fireplace contains hot humid air from outdoors. When the air
from outdoors contacts glass cooled below the dew point by your air conditioning, moisture in
that air will condense.
This is a result of normal operation and the flames will begin to yellow as the fireplace is
allowed to burn for 20 to 40 minutes.
Verify that the glass assembly is correctly installed and that all glass latches are engaged over
the tabs on the glass frame.
When first operated, this fireplace may release an odor for the first several hours. This is caused
by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor
may also be released from finishing materials and adhesives used around the fireplace. These
circumstances may require additional curing related to the installation environment.
This is a normal result of the curing process of the paint and logs. Glass should be cleaned
within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing pro-
cess. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary.
your dealer.
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the fireplace.
In an intermittent pilot ignition system (IPI), the pilot flame should turn off when appliance is
turned off. Some optional control systems available with IPI models may allow pilot flame to
remain lit.
NBV-IFT appliances are not approved for use with battery backup. Do NOT operate
this appliance with battery backup. This appliance will not be protected by the high
temp limit switch if battery backup is installed.
No action necessary. This appliance ships with a non-combustible material attached. Speci-
fications of the attached non-combustible material are listed in the Installer's Manual for this
appliance.
SOLUTIONS
Refer to Section 3 for more details.