Table 5 lists the electrical and mechanical specifications for the
OptiView T1/E1 and DS3/E3 WAN Analyzers.
Weight
: 1.7 kilograms (3.8 lbs.)
Size
: (H x W x D): approximately 4.1 cm x 21.1 cm x 32.8 cm (1.6 inches x 8.3 inches x 12.9
inches)
AC input
: 85 to 265 VAC; 47/63 Hz; 25 watts. Blue power LED indicator.
Test Access
:
T1/E1: In-line through connection using internal passive tap or an external in-line tap
Serial: Custom Fluke Networks Y-Cable
DS3/E3: External DS3/E3 passive tap
HSSI: Standard external Y-Cable
Network Analysis Interface
connectors), HSSI (standard 50-pin HSSI connector), and Serial (proprietary 36-pin D sub
connector for accessory Y-Cables).
Layer 2 Support: Frame Relay, PPP, and Cisco HDLC
Network Analysis LEDs
Capture Memory
Serial Configuration Port
Management Port
54
Table 5. Electrical and Mechanical Specifications
s: T1/E1 (dual IN/OUT RJ48 connectors), DS3/E3 (dual BNC
: Signal Status (DTE and DCE)
: 256 MB
: Serial RS-232 (9-pin male)
: 10/100 Ethernet (RJ45)