7 8 | Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Multi Zone Outdoor Units
7. Remove the terminal board (2 screws).
Figure 109
9.2.2 Removing the fan assembly
1. Follow steps outlined in Section 9.2.1.
2. Remove the hex nut xing the fan, and then remove the fan.
Figure 110
3. Remove the cover of electrical control box cover.
Figure 111
Data subject to change
4. Disconnect the fan motor connector CN14 from the IPM board.
Screws of
terminal board
Figure 112
5. Remove the four xing screws of the fan motor. Then remove the fan motor.