Every 100 Hours; Cleaning Air Cleaner Element; Cleaning Primary Air Filter Element - Kubota KJ-S130VX Operator's Manual

Diesel generator
Table of Contents

Advertisement

EVERY 100 HOURS

a Cleaning Air Cleaner Element
Since the air cleaner employed on this engine is a dry
type, never apply oil to it.
1. Open the evacuator valve once a week under
ordinary conditions - or daily when used in severe
or dusty conditions. This will get rid of large
particles of dust and dirt.
2. Wipe the inside air cleaner clean with cloth if it is
dirty or wet.
3. Avoid touching the element except when
cleaning.
4. When dry dust adheres to the element, blow
compressed air from the inside turning the
element. Pressure of compressed air must be
under 205 kPa (2.1 kgf/cm
z z z z z Engine model : D1703-EBG, V2203-EBGx x x x x
5. Replace the element every year or every 6
cleanings.
(1) Air cleaner body
(2) Element
(3) Wing bolt
(4) Evacuator valve
IMPORTANT:
¡ Make sure the wing bolt for the element is tight
enough. If it is loose, dust and dirt may be sucked
into the engine, causing premature wearing down
the cylinder liner and piston ring earlier, and
thereby resulting in poor power output and need
for engine repair.
2
, 30 psi).
z z z z z Engine model : V3300-EBGx x x x x
If the air cleaner is equipped with the secondary
element, start it in the following manner :
Take steps (1) through (4) foregoing.
5. Replace the primary element every year or every
6 cleanings. If the primary element is heavily
stained, replace it sooner. At this time, also
replace the secondary element.
6. The secondary element should be removed only if
it is to be replaced.
7. To protect the engine, do not remove the
secondary element in normal servicing of the
primary element.
(1) Air cleaner body
(2) Cover
(3) Secondary element
(4) Primary element
(5) Evacuator valve
IMPORTANT:
¡ Make sure hooking clip is tight enough. If it is
loose, dust and dirt may be sucked into the engine,
causing excessive wear or premature engine
failure and need for engine repair.
a Cleaning Primary Air Filter Element
To clean the element, use clean dry compressed air
on the inside of the element.
Air pressure at the nozzle must not exceed 205 kPa
(2.1 kgf/cm
2
, 30 psi).
Maintain reasonable distance between the nozzle and
filter.
MAINTENANCE
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents