OPERATING THE ENGINE

CAUTION:
3
To avoid personal injury:
¡ Read "Safe Operation" in the
front of this manual.
¡ Read the danger, warning and
caution labels located on the
generator.
¡ To avoid the danger of exhaust
fume poisoning, do not operate
the engine in a closed building
without proper ventilation.
¡ Always turn OFF the circuit
breaker before starting the
generator.
¡ Turn OFF all switches on the
electrical devices.
¡ C h e c k
connections of the electrical
devices before starting the
machine.
¡ DO NOT touch the charging
section during operation.
IMPORTANT:
¡ Do not use ether or any starting fluid for starting
the engine, or a severe damage will occur.
¡ To protect the battery and the starter, make sure
that the starter is not continuously turned for more
than 10 seconds.
STARTING THE ENGINE
1
. Turn OFF the circuit breaker on the
control panel.
[KJ-S130VX, KJ-S150VX]
(1) Circuit breaker
t h e
w i r i n g
a n d
OPERATING THE ENGINE
[KJ-T130DX, KJ-T180VX, KJ-T300, KJ-T160DX,
KJ-T210VX]
(1) Circuit breaker
2
. Turn OFF all switches for the electrical
devices.
3
. Turn the fuel tank tap to the "OPEN"
position.
(1) Fuel tank tap
(A) "OPEN"
CAUTION:
3
To avoid personal injury:
¡ N e v e r o p e n t h e d o o r o r
generator side cover while the
engine is running.
13