Manual Reset Mode With Intelligent Tap - Omron F3SG-SR Series Manual

Safety light curtain
Hide thumbs Also See for F3SG-SR Series:
Table of Contents

Advertisement

F3SG-SR/PG

Manual Reset Mode with Intelligent Tap

[Wiring Example]
F39-JG B-L/
XS5F-D521-DJ0-IL
IO-Link
Master * 5
F39-JG A-D
S1
Function
EDM
Interlock
Operating Range Selection
Non-Muting system
Test Input
Wired Synchronization
Timing chart
Beam state: Unblocked
Blocked
Reset switch (S)
OSSD
Note: 1. When using the Intelligent Tap (F39-SGIT-IL3) with the emitter and receiver connected, the following functions are not available.
• External Test
• Operating Range Selection by wiring
• Optical Synchronization
2. For the functional earth connection, refer to page 66.
70
F39-JGR3K-L and
F39-JG□B-L
F39-SGIT-IL3
* 6
IN
IN1
IN2
Safety controller
PLC * 2
* 3 * 4
DIP switch
EDM Disabled
3
4
Manual Reset (Start/
Restart Interlock)
5
Long
8
Perform wiring according to the wiring diagram.
N/A
N/A
Connect the emitter and receiver with the Intelligent Tap.
S1: Lockout/interlock reset switch
PLC: Programmable logic controller (Used for monitoring only.
Intelligent Tap
F39-JGR3K-D and F39-JG□B-D
Wiring for NPN * 1
24 VDC
24 VDC
Setting
[External device monitoring] : Disable
ON
ON
[Start interlock] : Enable
[Restart interlock] : Enable
ON
[Operating Range Selection] : Long mode
ON
[Muting] : Disable
NOT related to safety system.)
*1. Reverse the polarity of the power supply when using in the NPN
system. Select a PLC and a safety controller of PNP or NPN type
according to the system of your application.
*2. When connecting to the PLC, the output mode must be changed with
the SD Manager 3 according to your application. For the setting this
function, refer to the User's Manual (Man.No.Z405).
*3. Refer to page 75 for more information.
*4. The safety controller and the F3SG-SR must share the power supply
or be connected to the common terminal of the power supply.
*5. For connecting with the IO-Link Master unit, refer to an instruction
manual of the IO-Link Master unit you use.
*6. This is the case for a PELV circuit.
Needed
 : Indicates a switch position.
SD Manager 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-pg seriesF3sg-4sr seriesF3sg-4pga seriesF3sg-4sra0160-14F3sg-4srb0160-14F3sg-4sra0200-14-f ... Show all

Table of Contents