Input Circuit Diagram by Function

The input circuit diagrams of by function are shown below.
Test Input
<Light emission stops when connected to 24 VDC>
Emitter
main circuit
Operating Range Select Input
<Long>
5 V
Emitter
main circuit
RESET/EDM, MUTE A/B
<PNP>
Receiver
main circuit
*1. Short circuit current: approx. 9.5 mA (RESET/EDM),
approx. 4.5 mA (MUTE A/B)
<Light emission stops when connected to 0 V>
+24 VDC
Short circuit
current
Emitter
Approx. 5.0 mA
main circuit
0 VDC
<Short>
+24 VDC
Short circuit
current
Emitter
Approx. 4.2 mA
main circuit
0 VDC
<NPN>
+24 VDC
Short circuit
current *1
Receiver
main circuit
0 VDC
*2. Short circuit current: approx. 13.0 mA (RESET/EDM),
approx. 7.0 mA (MUTE A/B)
F3SG-SR/PG
Short circuit
current
Approx. 6.0 mA
5 V
Short circuit
current
Approx. 4.2 mA
Short circuit
current *2
+24 VDC
0 VDC
+24 VDC
0 VDC
+24 VDC
0 VDC