(Turning On The Water) - Pentair PRF 1035CS Service Manual

Matrix system 368/706w
Table of Contents

Advertisement

Available languages

Available languages

PLACING SOFTENER INTO OPERATION

(TURNING ON THE WATER)

Things You Might Need to Know
• When the controller is first plugged in, it may display a
flashing hourglass and the message Err 3, this means
that the controller is rotating the camshaft to the home
position.
• The preset default time of recharge is 00:00.
• The 706W Series controller is programmed to recharge
if a recharge has not taken place in the last 7 days. This
setting cannot be changed.
• Make sure control power source is plugged in. The
transformer should be connected to a non-switched
power source.
• Unless changed, the settings for a newly installed system
are:
Hardness - 250 ppm
Salt Setting - HE (High Efficiency)
Water Used Settings - 0 cubic meters
Internal System clock starts at 8:00 AM
The first recharge will occur when the system clock
reaches 00:00
Accessing History Values
The 706W control features a review level that displays the
operation history of the system. This is a great troubleshooting
tool for the control valve.
To access history values, press Recharge followed by the Salt
Amount button and hold for 3 seconds to view the Diagnostic
Codes.
NOTE: If a button is not pushed for 30 seconds the controller
will exit the history table.
Press the Time of Day button to increment through the table.
When the desired code is reached, Press the Salt Amount
button to display the value.
When the Salt Amount button is pressed to view H2 the current
flow rate will be displayed but not updated. Continue to press
and release the Salt Amount button every 5 seconds to update
the display. The flow icons on the display will flash when there
is flow thru the softener.
Code
Description
H1
Days since last recharge
H2
Current flow rate
H3
Current day of week
H4
Water used today since 0200
H5
Water used since last recharge
A0
Average water usage for day 0
A1
Average water usage for day 1
A2
Average water usage for day 2
A3
Average water usage for day 3
A4
Average water usage for day 4
A5
Average water usage for day 5
A6
Average water usage for day 6
Notes
Days since last recharge
Liters per minute
Current day of week
In cubic meters,
max value displayed 99.99
max value stored 655.35
ELECTRICAl SPECIFICATIONS:
SPECIFICATIONS:
INPUT: 120 - 220 V ~ 50/60 Hz 13 W
OUTPUT: 12 V ~ 0,5 A
SOFTENERS
OUTPUT: 12 V ~ 0,5 A
Matrix System 368/706W • 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4001593

Table of Contents