Download Print this page
Nectre Fireplaces WONDERFIRE AF18 Installation & Operating Manual

Nectre Fireplaces WONDERFIRE AF18 Installation & Operating Manual

Manual valve

Advertisement

Quick Links

WONDERFIRE F18 OF M NU L V LVE
INST LL TION & OPER TING M NU L
Nectre Wonderfire fire boxes are approved to be installed as a zero
clearance firebox and are designed to operate on Natural Gas.
Approval Number: AGA 4464 G
Installed primarily as a decorative appliance. Not certified as a Space Heater.
VERSION 1

Advertisement

loading

Summary of Contents for Nectre Fireplaces WONDERFIRE AF18

  • Page 1 WONDERFIRE F18 OF M NU L V LVE INST LL TION & OPER TING M NU L Nectre Wonderfire fire boxes are approved to be installed as a zero clearance firebox and are designed to operate on Natural Gas. Approval Number: AGA 4464 G Installed primarily as a decorative appliance.
  • Page 2 W RR NTY INFORM TION The benefits provided to you under the following warranty are in addition to any other rights and remedies available to you under the law. 1. Warranty during the first 10 years from the date of purchase (Firebox Warranty Period), there is a defect in the firebox of the Gas Burner;...
  • Page 3 INST LL TION NOTICE The installation of this appliance is only to be carried out by an authorised person in accordance with the Manufacturer’s Instructions, local gas fitting regulations, AS/NZS5601.1-2013 installation code for gas burning appliances and any other relevant statutory regulations. In all cases the installation of this appliance shall meet the requirements as set out in AS/NZS5601.1-2013 NOTE: A slight smell may be apparent for the first few hours of use.
  • Page 4 CONTENTS Contents .........................4 Data Plate .......................5 Dimensions ......................5 User Instructions.....................6 Installation Instructions ...................7 Servicing Details .....................9 Fault Finding Chart ....................10 Glen Dimplex contact information.................12...
  • Page 5 (Affixed to the base of the unit for reference to gas pressure & consumption) D T PL TE AF18 OF Manual valve (Eurosit 630) Injector Size (mm) N.G.C. (Mj/Hr) Natural Gas 1 x injector multiport 7 ports x 1.25 0.5kPa high/0.35kpa Low 35 high DIMENSIONS 320mm...
  • Page 6 USER INSTRUCTIONS • ALWAYS USE A FIREGUARD WHEN OPERATING THE FIRE IN THE PRESENCE OF CHILDREN OR THE INFIRM • ENSURE THAT CURTAINS CANNOT BLOW ACROSS THE FIRE OPENING ENSURE THAT THE CHIMNEY OR FLUE IS NOT BLOCKED • WASH HANDS AFTER HANDLING COALS AND ENSURE CHILDREN DO NOT HANDLE THEM AS THE COLOURING MAY CONTAIN TOXIC DYES G S FITTING REGUL TIONS The installation of gas appliances is covered by gas fitting regulations in most States which specify...
  • Page 7 INST LL TION INSTRUCTIONS Location Installation must meet Australian gas codes AS/NZS 5601. INSTALLATION CLEARANCES (where FFB is used)– Clearances from combustible materials Floor Sides 80mm Top / gather 50mm Flue outer 25mm Back 25mm PRELIMIN RY • This appliance must be installed by an Authorised person. •...
  • Page 8 (continued) INST LL TION INSTRUCTIONS • An AGA approved 150mm diameter Gas Cowl must be fitted. • The flue or chimney of an open gas fire must be kept clear at all times. Devices which close or temporally close the flue or chimney are not permitted. (e.g. a damper must be removed or securely disabled in the fully open position.) •...
  • Page 9 SERVICING DET ILS • The following notes are to assist a serviceman in the event of a malfunction. • Servicing must only be carried out by authorised personnel. • Spare parts and advice are available from Glen Dimplex on 1300 554 155. •...
  • Page 10 F ULT FINDING CH RT Fault Possible Cause Corrective Action Igniter Sparks but No Gas Check supply no Ignition Purge lines Gas Ignites but goes Thermocouple cable loose Tighten at rear of valve Thermocouple Faulty Replace Oxypilot Oxypilot Air inlet blocked Blow/clean out Gas pressure too low Pilot runs off mains pressure which must be at...
  • Page 12 GLEN DIMPLEX AUSTRALIA PTY LTD ABN 69 118 275 460 Head Office/Factory/Showroom 1340 Ferntree Gully Rd. Scoresby Vic 3179 Ph: 1300 554 155 Fax: (03) 8706 2001...