Nectre N900 Installation Instructions Free Standing Base Insert Keep these instructions for future reference Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA Revision A...
CONTENTS INSTALLATION INSTALLATION ................1 THE INSTALLATION INSTRUCTIONS IN THIS MANUAL IMPORTANT INFORMATION ..........1 APPLY TO THE NECTRE N900 OPEN FIREPLACE MODELS. FREE STANDING INSTALLATION ........2 2.1. POSITIONING THE OPEN FIREPLACE ......2 1. IMPORTANT INFORMATION 2.2. OPTIONAL FREE STANDING BASE ......2 2.3.
2.4. CORNER INSTALLATION 2.6. FLOOR PROTECTOR Dimensions given in the table and image below represent the Unless the open fireplace will be standing on a heat resistant minimum clearance (in millimetres) to combustible materials. floor such as concrete slab with slate or tiles, it will be necessary to provide a floor protector.
The flue kit is supplied with the freestanding open fireplace. clearances. Note that this flue kit is different to the one supplied with the Built-in model of N900. They are not interchangeable. The freestanding flue kit consists of: Single layer of continuous material with Minimum Air Gap of ...
The firebox can be installed on 50mm thick Skamotec 225 BUILT-IN INSTALLATION board with overall dimensions of 1000mm wide by 600mm deep. NOTE: Receiver for fan remote control must be fitted before If installed 250mm or more above the floor, the firebox installing the appliance.
Vented casing 3.4. FLOOR PROTECTOR (HEARTH) The dimensions of the floor protector are dependent on the height above the floor at which the heater is installed. Base of the firebox is 450mm or more above the floor – Floor protector must extend a minimum of 300mm in front of the firebox opening, and 200mm either side of the opening.
Insert the supplied M6 screw through the hole in the top freestanding model of N900. They are not interchangeable. of the receiver assembly, thread the spacers over the The Built-in flue kit consists of: screw, and then fasten the screw to the nutsert at the top of the bracket.
4.2. FLOOR PROTECTOR (HEARTH) 4. MASONRY INSTALLATION The minimum dimensions and construction materials for the floor protector when installed in a masonry fireplace are the NOTE: Receiver for fan remote control must be fitted before same as for a Built-In installation. Refer to section 3.4 Floor installing the appliance.
5. INSTALLING THE FIREBOX INTERNALS 1) Open spark arrestor and remove the box of bricks, grate and damper handle from inside the fireplace. 2) Bricks are placed in the retainer in a vertical orientation. Angle top edge of the brick towards the back of the firebox and slot under the retainer, allowing the bottom of the brick to sit on the horizontal lower shelf.