Page 1
Nectre N900 Operating Instructions Free Standing Base Insert Keep these instructions for future reference Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA Revision A...
OPERATING ............... 1 THE OPERATING INSTRUCTIONS IN THIS MANUAL APPLY 1.1. IMPORTANT INFORMATION ........1 TO THE NECTRE N900 OPEN FIREPLACE MODELS. 1.2. GENERAL OPERATION ..........2 THIS APPLIANCE HAS BEEN DESIGNED TO BURN HARDWOOD. DO NOT OVERFUEL BURNING SOFTWOOD 1.2.1.
1.2. GENERAL OPERATION CROSS SECTION SIDE VIEW OF DAMPER OPERATION 1.2.1. DAMPER The damper is a critical component of the fireplace and should be treated as such. With the damper open, smoke is able to escape the fireplace and into the flue, with it closed it will prevent cold air from entering the room while the fireplace is inactive.
Do not burn painted, impregnated/treated wood, The N900 Open Fireplace is fitted with an electric fan to manufactured board products or pallet wood. further enhance it’s heating performance. To operate, ensure the fan is plugged in (built-in installations will be plugged in during install) and use the supplied remote 1.5.
1.6. RUNNING THE APPLIANCE 1.8. ASH REMOVAL RELOAD WITH MORE WOOD ONLY REMOVE ASH TRAY WHILE FIREPLACE IS INACTIVE. Excess ashes should be removed when necessary, placed in a non-combustible container and moved outdoors immediately 1) Open the spark arrestor. to a location clear of combustible materials.
If a flue fire occurs: 1.12. TROUBLESHOOTING TIPS Shut the spark arrestor to prevent any falling debris from TROUBLE STARTING THE FIRE spilling out of the fireplace. Contact emergency services if flue fire worsens. Ash build up in the ashtray can obstruct the slots in the grate ...
2.2. REPLACING DAMPER COMPONENTS The damper plays a critical role in the safe and efficient operation of the open fireplace. It allows smoke to escape the fireplace during operation and keeps warmth in the house when the fireplace is not in use. Over time the damper plate may begin to warp, this is normal and will not affect its function.
2.3. ADJUSTING THE SPARK ARRESTOR Angle bottom edge out and remove the top end of the hinge rod from its locating hole. Pull down to remove. The spark arrestor is designed with the ability to be flipped, to reverse which way it opens. ONLY ADJUST THE SPARK ARRESTOR WHILE THE FIREPLACE IS INACTIVE.
REPLACING THE FAN and re-install by repeating steps 2 and 1. The fan installed in the N900 Open Fireplace is rated to high 5) Place spark arrestor stop in its locating hole on the temperatures, but after years of use it may be necessary to opposite side.
Page 10
10) To remove the receiver, using a 10mm socket, undo the 2 nuts holding the ducting outtake to its studs and pull forward to remove, exposing the receiver. 11) Pull the receiver assembly through the cut-out in the rear panel and unplug the 2 wiring connectors. 12) Reverse steps to reinstall the fan assembly and fan receiver.
Page 11
INSERT/INBUILT FAN AND RECEIVER REMOVAL (Numbers correspond to steps in Section 2.4)