The UPS Provides a Safe Shutdown Process during AC Power Failure
Because the NS1000 system uses a Linux Based OS, the KX-NS1000 must be powered down using the
Shutdown process to avoid possible damage to the systems File Structure.
UPS Connection diagram and automatic shutdown process
AC
Power
1. AC power is lost.

1.2 System Shutdown with UPS

2. The UPS supplies power to
the PBX (Using its battery).
AC Cable
UPS
USB Cable
3. The UPS notifies that AC power is
lost and it's remaining battery life.
NB: When NS1000 is 'Shutdown', it will not power back on automatically when
power is restored – the AC Switch needs to be switched OFF/ON
NS1000 Power requirements (from the nameplate ratings)
Peak – 138VA (Watts)
RMS – 98VA (Watts)
RS232C is not supported for UPS
USB
Port
programmed battery threshold.
4. KX-NS1000 executes
self shutdown at pre-