Specification About The Thermal Protection - Pioneer PDP-5071PU Service Manual

Plasma display system
Table of Contents

Advertisement

1
10.5

SPECIFICATION ABOUT THE THERMAL PROTECTION

∗ The change of HI / LO have hysterisis curve below.
Reading Value of The Sensor and FAN Drive.
A
T4
(Outside air 131F)
T3
(Outside air 100F)
T2
(Outside air 94F)
B
T1
(Outside air 82F)
T0
(Outside air 77F)
FAN: STOP
FAN: LO
Pin 76
C
Operation when executing FAN control command
When executing [FCNS00], [FCNS01], [FCNS02] command, detect the FAN_NG signal. When NG is detected,
it becomes shutdown. When [FCNS03] command is executed, FAN_NG detection is not operated.
Pin 149
(FAN_CONT)
D
Pin 17
(FAN_CONT_POW)
Set State and FAN Drive
Power
ON
OFF
[ Outline Circuit ]
E
F
188
1
2
FAN: HIGH
AD Value
Assign
10bit
TEMP2
T4 setting
424
T3 setting
566
T2 setting
601
T1 setting
653
T0 setting
679
Assign
FAN: HIGH FAN: LO
H
H
PSW1
State
ON
ON
According to the reading value of above table sensor.
STB
FAN_CONT: "L"
H : Vo = 11V
L : Vo = 7.6V
17
U-COM
149
FAN_CONT
2
3
FAN: LO
FAN: STOP
AD Value
Sensor
8bit
Temp.
(Outside Air)
106
268F
142
104F
150
97F
163
86F
170
80F
OFF
This model control the FAN drive by pin 149 (FAN ON / OFF)
and pin 17 (Change of FAN control voltage) of MAIN U-com.
H
L
L
Control
Vo
FAN_vcc
15
REG
Vref = 2.64V
47
33
H: On
L: Off
PDP-5071PU
3
4
FAN: LO
FAN: HIGH
Aims
131F
SD
Low → High
100F
High → Low
94F
STOP → Low
82F
Low → STOP
77F
Fan Operation
HIGH or LO
OFF
4
SD