Qip; Qaj - Pioneer PDP-5071PU Service Manual

Plasma display system
Table of Contents

Advertisement

1

9.3.3 QIP

7 Acquisition of other data on the panel • • • [QIP]
The command QIP is for acquiring data on operational information of the panel.
A
Command
Effective Operation
Format
[QIP]
All operations
Data Arrangement
ECO
1
SERIAL
2
HOUR METER
B
3
TOTAL HOUR METER
4
PON COUNTER
5
TEMP1 acquisition (Temperature value)
6
TEMP0 acquisition (Temperature value)
7
MAX-TEMP1 acquisition (Temperature value)
8
Reserved
CS
C

9.3.4 QAJ

7 Acquisition of panel adjustment data (common data) • • • [QAJ]
The command QAJ is for acquiring the panel's factory-preset data.
Command
Effective Operation
Format
[QAJ]
All operations
D
Data Arrangement
ECO
1
V-SUS adjustment value
2
V-OFT adjustment value
3
V-RST-P adjustment value
4
Reserved
5
XSB adjustment value
6
YSB adjustment value
E
7
YTG adjustment value
8
YTW adjustment value
9
RSW adjustment value
10
YTB adjustment value
11
RYW adjustment value
12
R-REVICE setting value
13
G-REVICE setting value
14
B-REVICE setting value
CS
F
• For each REVICE setting value, the level set for RRL, RGL, or RBL is transmitted as one character.
172
1
2
Modes
To acquire data on operations of the panel Return data: 3 (ECO)+58(DATA)+2(CS)= 63 Byte
Data
Length
3 Byte
15 Byte
8 Byte
8 Byte
8 Byte
5 Byte
5 Byte
5 Byte
4 Byte
2 Byte
Modes
To acquire data on operations of the panel Return data: 3 (ECO)+41(DATA)+2(CS)= 46 Byte
Data
Length Output Example
3 Byte
QAJ
3 Byte
128
3 Byte
128
3 Byte
128
∗∗∗
3 Byte
3 Byte
128
3 Byte
128
3 Byte
128
3 Byte
128
3 Byte
128
3 Byte
128
3 Byte
128
1 Byte
0
1 Byte
0
1 Byte
0
2 Byte
B7
2
3
Function
Output Example
QIP
- - - - - - - - - - - - - - -
00000000
00000000
00000000
+23.5(*)
+28.7(*)
+78.3(*)
∗∗∗∗
94
Function
PDP-5071PU
3
4
Remarks
(*) : Centigrade scale
Remarks
4