Bosch MIC IP ultra 7100i User Manual page 78

Hide thumbs Also See for MIC IP ultra 7100i:
Table of Contents

Advertisement

78
en | Status Codes
Status
Code
8
9
10
2020-11 | 1.4 |
Description
Camera may be operating in an
environment where ambient
temperature is above specification
of the camera.
Camera has been subjected to high
shock. Mechanical damage to the
camera may exist.
Camera is detecting high humidity
level inside housing. The integrity of
the housing seal may be
compromised.
User Manual
MIC IP ultra 7100i │ MIC IP starlight 7100i
Recommended action
(to be completed by a qualified Service
Technician)
2. Review the diagnostic log of the camera
(accessible from the Service menu) for errors
related to the operation of the internal
heaters.
Note: Motorized zoom and focus functions of
the visible camera lens will be disabled until
the camera operates within the specified
temperature range.
1. Verify that the ambient temperature is not
above +65 °C (+149 °F).
2. Review the diagnostic log of the camera
(accessible from the Service menu) for errors
related to the operation of the internal fan.
3. Add the optional sunshield accessory to
reduce internal heating caused by sun
loading.
1. Verify the integrity of the mechanical parts
such as the arms and the pan body.
2. Verify the integrity/tightness of the
external fasteners. Tighten where necessary.
3. If obvious damage is present, stop using
the camera and contact the nearest Bosch
Security Systems Service Center.
4. If no damage is evident, power the camera
off and then on, and then evaluate
operational performance. If the camera does
not operate as expected, contact the nearest
Bosch Security Systems Service Center.
1. Inspect the window for any cracks or
obvious damage around the edge of the
window.
2. Verify the integrity/tightness of the
external fasteners. Tighten where necessary.
3. Verify the integrity of the mechanical seals
around the tilt head, pan body, and arm
joints.
4. If damage to the seals is obvious, contact
the nearest Bosch Security Systems Service
Center.
5. If no obvious damage is found, power the
camera off and then on. If the status code
reappears, contact the nearest Bosch
Security Systems Service Center.