Sound Power Rating; Capacity Ratings - (Ari 210/240); Gas Heat Ratings; 2 Stage Gas Heat Ratings - York SUNLINE 2000 DM 048 Technical Manual

Single package gas/electric units and single package air conditioners
Table of Contents

Advertisement

036-21502-003-A-1105
TABLE 1: SOUND POWER RATING
ESP
UNIT
CFM
SIZE
IWG
SPEED
036
1,200
0.6
LOW
048
1,600
0.55
HIGH
060
2,000
0.45
HIGH
072
2,200
0.3
HIGH
1. These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field. The
dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan
manufacture has no way of knowing the details of each system. This constitutes and expectation to any specification or guaran-
tee requiring a dBA value or sound data in any other form than sound power level ratings.
2. At a distance of 10 feet from the blower.
TABLE 2: CAPACITY RATINGS - (ARI 210/240)
MODEL
DM036
DM048
DM060
DM072
1. 80/67°F Indoor and 95°F outdoor.
2. EER = Energy Efficiency Ratio at full load - the cooling
capacity in Btu's per hour (Btuh) divided by the power
input in watts, expressed in Btuh per watt (Btuh/watt).
3. SEER = Seasonal Energy Efficiency Ratio.
TABLE 4: 2 STAGE GAS HEAT RATINGS
MBH INPUT
1
MODEL
ST
1
STAGE 2
DM036D06
45
DM036D10
69
DM048D06
45
DM048D10
75
DM060D06
45
DM060D10
75
DM072D06
45
DM072D10
75
1. Models are 3Ø only.
Unitary Products Group
1
BLOWER
KW
63
125
0.60
84
84
0.80
85
85
1.00
86
86
1.35
87
87
1
2
MBH
EER
SEER
36.0
9.1
10.0
47.4
9.0
10.0
59.0
9.1
10.0
72.0
9.0
-
MBH OUTPUT
ND
ST
ND
STAGE 1
STAGE 2
75
35.8
60.8
115
55.2
75
35.7
60.8
125
60.4
100.6
75
35.8
60.8
125
60.4
100.6
75
35.8
60.8
125
60.4
100.6
SOUND POWER (db 10
Octave Band Centerline Frequency (Hz)
250
500
1,000
74
67
69
75
68
70
76
69
71
77
70
72
TABLE 3: GAS HEAT RATINGS
3
MODEL
DM036N04
DM036N08
DM048N06
DM048N10
DM060N08
DM060N10
DM072N08
DM072N10
1. All units are single-stage heating.
STEADY STATE EFFICIENCY
ST
ND
STAGE
1
STAGE
2
79.4
92
80.0
79.4
80.5
79.4
80.5
79.4
80.5
-12
Watts)
2,000
4,000
8,000
62
57
52
63
58
53
64
59
54
65
60
55
1
MBH
MBH
AFUE
INPUT
OUTPUT
(%)
50
40
80.9
100
80
80.5
75
60
80.9
125
100
80.3
100
80
80.5
125
100
80.3
100
80
80.5
125
100
80.3
RISE
MINIMUM HEATING
AIRFLOW (CFM)
STAGE
MIN.
MAX.
81.1
35
70
80.2
55
90
81.1
25
70
80.5
45
75
81.1
35
70
80.5
45
75
81.1
35
70
80.5
45
75
dB(A)
SWL
@
dB(A)
2
10Ft.
74
41
75
42
76
43
77
44
TEMP
RISE ºF
15 - 45
40 - 70
25 - 55
45 - 75
25 - 55
35 - 65
25 - 55
35 - 65
790
950
790
1230
1010
1230
1230
1230
15