TABLE 14: PHYSICAL DATA
Evaporator
Blower
Evaporator
Coil
Condenser
Fan
(2 per Unit)
Condenser
Coil
(2 per unit)
Refrigerant
Charge
Compressors
Air Filters

OPTIONS/ACCESSORIES

ELECTRIC HEAT ACCESSORIES

Electric heaters are available as field installed accessories.
Refer to electric heat instructions for installation. These heat-
ers mount in the heat compartment with the heating elements
extending into the supply air chamber. All electric heaters are
fused and intended for use with single point power supply.

ELECTRIC HEAT OPTION

The factory-installed heaters are wired for single point power
supply. Power supply need only be brought into the single
point terminal block.
These CSA approved heaters are located within the central
compartment of the unit with the heater elements extending
into the supply air chamber.
Fuses are supplied, where required, by the factory. Some kW
sizes require fuses and other do not. Refer to Table 15 for
minimum CFM limitations and to Tables 8 through 13 for elec-
trical data.
Unitary Products Group
Component
Blower, Centrifugal (Dia. X Wd. in.)
Motor, Standard (HP)
Motor, Optional (HP)
Rows
Fins per Inch
DM
Height (in.)
Face Area (ft.
Propeller Dia. (in., each)
Motor (HP, each)
DM
CFM, Nominal (each)
Rows (each)
Fins per Inch
DM
Height (in. each)
Face Area (ft.
System 1 (lb./oz.)
DM
System 2 (lb./oz.)
Quantity
DM
Size (Wd. x Ht. x Thickness in.)
Number Per Unit
15 x 15
2
each)
2
each)
Type
25x20x2
TABLE 15: MINIMUM SUPPLY AIR CFM
Heater
kW
Voltage
9
18
24
380
36
54

MOTORIZED OUTDOOR DAMPER

The Motorized Outdoor Damper can be a factory installed
option or a field installed accessory. If factory installed, refer
to the instructions included with the outdoor air hood to com-
plete the assembly. Field installed Motorized Outdoor
Damper accessories include complete instructions for instal-
lation.
Models
090
120
15 x 15
1-1/2
2
2
3
2
2
15
15
32
40
10.6
13.2
24
24
1/3
3/4
3400
4400
1
1
20
20
28
44
9.2
14.5
4/12
6/12
4/6
6/12
2
2
Recip
Recip
25x20x2
4
4
Unit Model Size, Nominal Tons
7.5
10

Minimum Supply Air CFM

2250
N/A
2250
3000
2250
3000
2250
3000
N/A
3000
150
15 x 15
3
5
3
15
40
13.2
24
3/4
4400
2
20
44
14.5
10/12
9/8
2
Recip
25x20x2
4
12.5
N/A
3750
3750
3750
3750
21