Download Print this page
HP ProCurve Networking J8454A Quick Start Manual

HP ProCurve Networking J8454A Quick Start Manual

Secure router dl 1xe1 module

Advertisement

Quick Links

Quick Start Guide
ProCurve Secure Router dl 1xE1 Module
J8454A
S
PECIFICATIONS
Operating Modes
E1/FE1 Frame Relay, E1/FE1 PPP, E1/FE1 Multilink
Frame Relay, E1/FE1 Multilink PPP, E1/FE1 HDLC
E1/FE1 Interface
Supported Standards: ITU-T G.703, ITU-T G.797,
ITU-T G.704 (CRC-4), ITU-T G.823
Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Receiver Sensitivity: -30 dB
FE1 Line Rate: Channelized timeslot (in multiples of
56/64 kbps)
Connector: RJ-48C
Clock Source
Network, internal
Diagnostics
Test Pattern Generation and Detection: QRSS, 511,
all ones, all zeros
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and 24 hours)
Compliance
FCC Part 15 Class A, EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13
EN 60950, IEC 60950, AS/NZS 60950
Physical
Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at
30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to
158°F)
Non-Operating Relative Humidity: Up to 95 percent,
noncondensing at 30°C (86°C)
Altitude: Up to 3.05 km (10,000 ft)
61195868L1-13C, August 2005
5990-8864
I
I
NSTALLATION
NSTRUCTIONS
1.
Remove power from the unit.
2.
Slide the option module into the option slot until the module is
firmly seated against the chassis.
3.
Secure the screws at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
Note
For safety information for the routers and all
modules, please refer to the safety and ESD
precautions in the ProCurve Secure Router
Installation Guide included in your router shipment.
E1 N
(RJ-48C) C
ETWORK
Pin
Name
1
R1
2
T1
3
4
R
5
T
6-8
Note
An optional backup module is required for backup
applications.
For a description of the backup connection pinouts,
refer to the Quick Start Guide included with your
backup module
www.procurve.com
P
ONNECTION
INOUT
Description
Receive data from the network
Receive data from the network
Unused
Transmit data toward the network
Transmit data toward the network
Unused
Copyright 2005 Hewlett-Packard Development Company, LP

Advertisement

loading

Summary of Contents for HP ProCurve Networking J8454A

  • Page 1 Quick Start Guide 5990-8864 ProCurve Secure Router dl 1xE1 Module J8454A NSTALLATION NSTRUCTIONS Remove power from the unit. Slide the option module into the option slot until the module is firmly seated against the chassis. Secure the screws at both edges of the module. Connect the cables to the associated device(s).
  • Page 2 Quick Start Guide 5990-8864 ProCurve Secure Router dl 1xE1 Module J8454A E1 M ODULE OMMANDS clock source [line* | internal] sa4tx-bit [0 | 1*] Configures the source timing used for the interface. Use the no form of this command Selects the Tx value of Sa4 on this E1 interface. Use the no form of this command to to return to the default value.