General Operating Parts; Fuel Specifications; Good Faith Wall Surface/Tv Guidelines - Heatilator HEIR36H-IFT Owner's Manual

Hide thumbs Also See for HEIR36H-IFT:
Table of Contents

Advertisement

B. General Operating Parts
Figure 3.2 references the general operating parts of the
appliance and the section of this manual in which they are
discussed.
DECORATIVE FRONTS
(NOT SHOWN)
SECTION 4.B.
OPERATION DURING
A POWER OUTAGE
SECTION 3.i.
FIXED GLASS ASSEMBLY
(NOT SHOWN)
SECTION 4.B & 4.C
CLEAR SPACE
SECTION 3.A.
RATING PLATE/GLASS CLIP TOOL LOCATION
Figure 3.2 General Operating Parts
Rating Plate/Glass Clip Tool Location
The rating plate for this model is located underneath the
firebox affixed to a tray that must be accessed using a
1/4 inch nut driver. See Figure 3.3. To access the rating
plate, remove the screw that secures the tray to the appli-
ance bottom and pull the tray out.
The glass clip removal/installation tool is also located in
this area. To access the glass clip tool, remove the screw
that secures it to the appliance bottom.
RATING PLATE
RATING PLATE
Figure 3.3 Rating Plate/Glass Clip Tool Location
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner's Manual • 2458-981 Rev. N • 10/20
8
MANTEL
SECTION 3.B.
GLASS CLIP TOOL
GLASS CLIP TOOL
C. Fuel Specifications
WARNING! Risk of Fire or Explosion! Appliance must
be set up for compatible gas type!
• This appliance is designed to operate on either natural
gas or propane. Make sure the appliance is compatible
with gas type selected for installation site.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
D. Good Faith Wall Surface/TV Guidelines
FIREPLACE OPENING
Figure 3.4. Good Faith Wall Surface Temperatures Above Appliance
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 degrees or
more depending on the thermometer settings and material
characteristics being measured.
CEILING
150°F
160°F
52 IN. MIN.
155°F
46 IN.
160°F
40 IN.
34 IN.
165°F+
28 IN.
180°F+
22 IN.
230°F+
16 IN.
10 IN.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT