Hide thumbs Also See for HEIR36H-IFT:
Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
HEIR36H-IFT
HEIR36T-IFT
HEIR42H-IFT
HEIR42T-IFT
HEIR50H-IFT
HEIR50T-IFT
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator HEIR36H-IFT

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 2: Table Of Contents

    B. Securing and Leveling the Appliance ....34 C. Installing Non-Combustible Facing Material ..35  = Contains updated information. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed ____________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2458-982 12/16 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 4: Product Specific And Important Safety Information

    HEIR42T-IFT (0-2000 FT) 54,000 30,000 (NG) HEIR42H-IFT HEIR42T-IFT (0-2000 FT) 47,500 23,500 (LP) HEIR50H-IFT HEIR50T-IFT (0-2000 FT) 65,000 36,000 (NG) HEIR50H-IFT HEIR50T-IFT (0-2000 FT) 57,500 30,250 (LP) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 6: Getting Started

    Reciprocating saw Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 7: Inspect Appliance And Components

    Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 8: Framing And Clearances

    Millimeters 1549 35-7/8 23-1/2 39-7/8 1013 59-1/4 1505 31-1/16 57-5/8 1464 29-5/8 35-3/16 3-7/8 34-3/16 2-3/4 54-15/16 1395 10-7/8 41-3/8 1051 16-1/8 Figure 3.1 Appliance Dimensions (HEIR36) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 9 1368 73-5/16 1862 40-1/16 1018 66-5/8 1692 36-11/16 44-3/16 1122 3-7/8 43-3/16 1097 2-3/4 63-15/16 1624 10-7/8 50-3/8 1280 16-1/8 Figure 3.2 Appliance Dimensions (HEIR42 & HEIR50) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 10 46-11/16 IN. (1186 mm) (1186 mm) 3-9/16 IN. 1-1/4 IN. 3-9/16 IN. 1-1/4 IN. (91 mm) (32 mm) (91 mm) (32 mm) Figure 3.4 Decorative Front Dimensions (HEIR42-IFT) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 11 54-11/16 IN. (1389 mm) (1389 mm) 3-9/16 IN. 1-1/4 IN. 3-9/16 IN. 1-1/4 IN. (91 mm) (32 mm) (91 mm) (32 mm) Figure 3.5 Decorative Front Dimensions (HEIR50-IFT) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 12: Clearances To Combustibles

    78-9/16 65-9/16 111-1/16 28-5/8 23-1/2 32-13/16 HEIR42 Millimeters 1995 1665 2821 Inches 84-1/4 73-9/16 119-1/8 31-1/2 23-1/2 36-13/16 HEIR50 Millimeters 2140 1868 3026 Figure 3.6 Appliance Locations Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 13 2 X 4 ONLY IN GRAY AREA NOTE: 2 X 4 HEADER CONFIGURATION 39 IN. 1 IN. FACTORY-SUPPLIED 1/2 IN. NON-COMBUSTIBLE BOARD = COMBUSTIBLES NOT ALLOWED Figure 3.7 Non-Combustible Zone Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 14 3.D. Inches 73-9/16 HEIR50 Millimeters 1651 1868 1321 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 3.8 Clearances to Combustibles (2 X 4 Construction) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 15 ** 2 x 4 material must be framed down from 2 x 6 rough opening height B’ to rough opening height B. * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 3.9 Clearances to Combustibles (2 x 6 Construction) Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 16: Constructing The Appliance Chase

    • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace may cause overheating and a fire. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 17: Hearth Extension

    1811 FLOOR OR PLATFORM Figure 3.12 Appliance Raised a Minimum of 3 Inches Above Combustible Surface. Non-Combustible Hearth Figure 3.10 Non-Combustible Hearth Extension Dimensions Extension NOT REQUIRED. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 18: Termination Location And Vent Information

    * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 19: Chimney Diagram

    2 sides beneath the floor. • Vinyl protection kits are required for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 20: Approved Pipe

    DVP12 8-1/2 DVP24 DVP36 25-1/2 DVP48 1219 DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.4 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 21: Measuring Standards

    • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.6 Measure to Outside Mounting Surface Figure 4.7. Measure to Top of Last Section of Pipe Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 22: Vent Diagrams

    12.2 m After V = 6 ft then H = 2 x V ft Maximum = 60 ft Maximum *when used with approved termination caps Figure 4.8 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 23 3.7m 9 ft 2.7 m 14 ft 4.3 m 10 ft 3.0 m 16 ft 4.9 m = 60 ft Maximum = 20 ft Maximum Figure 4.9 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 24 Max = 2 X V must be adhered to. has no specific restrictions EXCEPT, = 2 x V and V cannot exceed 60 ft Maximum t max total total Figure 4.10 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 25 Note: Exhaust restrictor is permitted ONLY on 11 ft. minimum vertical runs with no elbows. = 50 ft. Max. (15.2 m) = 2 ft. Min. (610 mm) Figure 4.11 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 26 See Figure 4.12. 6. Reinstall the top refractory. Vertical HEIR36 HEIR42 HEIR50 Pipe Up to 10 ft. Restrictor Restrictor Restrictor 11-30 ft. 31-50 ft. Table 4.1. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 27 12 ft 3.7 m *No specific restrictions on this value EXCEPT = 50 ft (15.2 m) Max. After V = 6 ft, then H Max.= V Figure 4.14 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 28 EXCEPT, after V = 6 ft, then H Max = 2 x V Total = 50 ft (15.2 m) Max. Total + Total INSTALLED HORIZONTALLY Figure 4.15 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 29: Pvlp-Slp And Pvi-Slp-B Information

    Table 4.3. must still be met. Allowable Baffle Distance from PVLP-SLP to Appliance Minimum Maximum 2-15 ft. 1-1/2 in. 2-1/2 in. 16-39 ft. Closed 1-1/2 in. Greater than 40 Closed Table 4.3 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 30: Vent Clearances And Framing

    (refer to Section 12.A.) attached to them. • See Section 7.E. for information for regarding the instal- lation of a horizontal termination cap. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 31: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 32: Installing The Optional Heat-Zone ® Gas Kit

    Note: Only one Heat-Zone Gas Kit may be used with this ® appliance. HEAT ZONE LOCATION ® LEFT AND RIGHT SIDES Figure 5.5 Heat Zone Cover Plate Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 33: Appliance Preparation

    3. Ensure gasket seal is in place prior to installing vent pipe sections. Gasket is installed at the factory. LOGS SEAL CAP FINISHING TEMPLATES SPLATTER GUARD LAVA ROCK HEAT SHIELDS Figure 6.1 Shipping Location of Components Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 34: Securing And Leveling The Appliance

    • Optional: Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance. Figure 6.5. Heat Shields and Nailing Tabs in Installation Position Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 35: Installing Non-Combustible Facing Material

    • Use a wet or dry towel or soft brush to remove dust or dirt from facing material. • See Section 10 for finishing materials guidelines. Figure 6.7 Installing Non-Combustible Facing Material Figure 6.6 Shipping Location of Non-Combustible Board Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 36: Venting And Chimneys

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Figure 7.4 Seams Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 37: Secure The Vent Sections

    Figure 7.7 Rotate Seams for Disassembly connection point to appliance. 120º Figure 7.8 Align and Disassemble Vent Sections Figure 7.5 Securing Vertical Pipe Sections 120º Figure 7.6 Securing Horizontal Pipe Sections Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 38: Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.10. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 39: Horizontal Termination Requirements

    (SEE CHART BELOW) • Use an extended heat shield if the finished wall Figure 7.13 Venting Through the Wall thickness is greater than 7-1/4 in. (184 mm). Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 40: Electrical Information

    ACCESS THROUGH LEFT COLUMN ACCESS THROUGH FIREBOX (Prior to installation of non-combustible board) (After installation of non-combustible board) GASKET COVER Figure 8.1 Junction Box Access Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 41: Wiring Requirements

    Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 42 ADAPTER MODULE RESET SWITCH WIRE ASSEMBLY ELECTRONIC CONTROL MODULE RF MODULE 6 PIN APPLIANCE 6V DC ON/OFF BATTERY PACK CONTROL (OPTIONAL) Figure 8.3 IntelliFire™ Touch Wiring Diagram Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 43: Gas Information

    Check with your local gas utility to determine proper • If substituting for these components, please consult orifice size. local codes for compliance. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 44: Air Shutter Setting

    This is due to the different chemical compositions that make up both fuel types. In general, the LP flames may be a little shorter and much brighter than a natural gas flame. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 45: Finishing

    NOTICE: Surface temperatures around the appliance will become warm while the appliance is in operation. Ensure finishing materials used for all surfaces (floor, walls, mantels, etc.) will withstand temperatures up to 190°F. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 46: Finishing Templates

    Contact your dealer to order the correct Arch Template Kit for your fireplace model. SIDE FINISHING TEMPLATES Figure 10.4 Top and Side Finishing Template Locations 1-1/4 IN. Figure 10.2 Top Finishing Template Bend Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 47 Figure 10.5 Finishing Template Bends Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 48: Mantel And Wall Projections

    BOARD CLEARANCES 14 IN. MIN. FIREPLACE OPENING COMBUSTIBLE OR NON-COMBUSTIBLE WALL Figure 10.7 Non-Combustible Mantel Leg and Wall Projections Figure 10.9 Combustible Mantel Allowance - HEIR36  Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 49 = 44-3/16 IN. (HEIR50) = 40-3/16 IN. (HEIR42) HEIR50 HEIR42 1-1/4 IN. FIREPLACE FIREPLACE OPENING OPENING Figure 10.13 Non-Combustible Mantel Allowance - HEIR42 Figure 10.11 Combustible Mantel Allowance - HEIR50 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 50: Decorative Front Dimensions For Finishing

    1 inch. FIRESCREEN DECORATIVE FRONTS RECTANGULAR ARCHED* FS-36-XX-HTL FS-36A-XX-HTL* FS-42-XX-HTL FS-42A-XX-HTL* FS-50-XX-HTL FS-50A-XX-HTL* *Requires Arch Template Kit (not included) Table 10.1. Approved Decorative Fronts Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 51: Appliance Setup

    CAUTION! Risk of Injury! DO NOT put fingers under glass frame. Fingers may get pinched by glass frame during removal. Figure 11.1. Glass Clip Tool Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 52 CAUTION! Risk of Injury! DO NOT put fingers under glass frame. Fingers may get pinched by glass frame during installation. Figure 11.8. Securing Bottom Glass Clips Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 53: Remove The Shipping Materials

    APPLY GLOWING EMBERS ADJACENT TO PORTS Figure 11.10. Location of Glowing Embers Figure 11.9. Apply Mystic Embers Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 54: Install The Log Assembly

    Log should be positioned as shown in Figure 5. LOG CONTACTS GRATE TINE LOG STOP RESTS AGAINST BACK OF CENTER GRATE TINE Figure 5. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 55 Rest top of Log #4 in notch on top left corner of Log #1. See Figure 3 and Figure 9. BURNED PORTION LOG #4 CONTACTS BURNED EDGE BACK OF LOG #2 Figure 8. Figure 9. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 56 LOG DOES NOT CONTACT GRATE TINE 1/2 INCH HEIR42 SHOWN 1/2 INCH Figure 12. Log #5 Placement Figure 13. Log #6 Placement Figure 14. Log Set Installed. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 57: Log Placement Instructions

    LOG CONTACTS GRATE TINE Figure 5. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 58 1-1/2 inches from right grate tine. The center of the log should rest in notch on Log #3 and the top of Log #5 should rest in the notch on Log #1. BURNED EDGE NOTCH FOR LOG #6 LOG CONTACTS REFRACTORY 1-1/2 IN. (APPROXIMATELY) Figure 10. Figure 11. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 59: Install Decorative Front

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 60: Reference Materials

    (508 MM) 6 in. 14 IN. (152 mm) (356 MM) 12 IN. (305 MM) DVP-WS (Wall Shield Firestop) DVP-RDS ROOF DECK INSULATION SHIELD Figure 12.1 DVP vent components Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 61 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Figure 12.2 DVP vent components Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 62 9-1/2 in. Cap Shield (352 mm) (241 mm) 26 in. 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 12.3 DVP Vent Components Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 63 A. Vent Components Diagrams (continued) 12 in. 305 mm 7-1/4 in. (184 mm) 12-1/2 in. (318 mm) 5-1/4 in. (133 mm) DVP-TVHW VerticalTermination Cap (Highwind) Figure 12.4 DVP vent components Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 64 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. (318 mm) SLP-LPC SLP Low Profile Cap (Approved for use with PVI-SLP-B only) Figure 12.5 PVI-SLP-B Vent Components Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 65 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.6 PVLP-SLP Vent Components Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...
  • Page 66: Accessories

    Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer, please visit www.heatilator.com. Printed in U.S.A. - Copyright 2017 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17...

Table of Contents