Maintenance Tasks - Qualified Service Technician - Heatilator HEIR36H-IFT Owner's Manual

Hide thumbs Also See for HEIR36H-IFT:
Table of Contents

Advertisement

Remote Control
Frequency: Seasonally
By: Homeowner
Tools needed: Replacement batteries and remote con-
trol instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Replace batteries as needed in remote transmitters.
• Place remote control out of reach of children.
If not using your fireplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
• Remove batteries from remote controls.
• Turn the ON/OFF/REMOTE switch on the control module
to OFF.
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such as plants, bird nests, leaves, snow,
debris, etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and flashing remains
intact.
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner's Manual • 2458-981 Rev. N • 10/20
C. Maintenance Tasks - Qualified Service
Technician
The following tasks must be performed by a qualified ser-
vice technician.
Glass Cleaning
(Exterior and Interior of Installed Glass)
Frequency: Seasonally
By: Qualified Service Technician
Tools Needed: Protective gloves, ceramic glass cleaner,
drop cloth and a stable work surface.
WARNING! Risk of Injury! Glass installation and re-
moval must be performed only by a qualified service tech-
nician.
CAUTION! Handle fixed glass assembly with care.
Glass is breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
• DO NOT clean glass while it is hot
NOTICE! Use only glass cleaner compatible with ce-
ramic glass. Other types of glass cleaner may damage
the glass surface when exposed to high temperatures.
• Prepare a work area large enough to accommodate fixed
glass assembly and door frame by placing a drop cloth
on a flat, stable surface.
Note: Fixed glass assembly and gasketing may have res-
idue that can stain carpeting or floor surfaces.
• Remove decorative front from fireplace and set aside
on work surface.
• See appliance installation manual for instructions to
remove fixed glass assembly.
• Clean glass with a non-abrasive commercially available
ceramic glass cleaner.
- Light deposits: Use a soft cloth with soap and water.
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer).
• See appliance installation manual for instructions to
replace the fixed glass assembly.
• Inspect and operate all glass latches to ensure they
move freely and no obstructions are present.
• Reinstall decorative front.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect fixed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.