Advertisement

Published Manual Number/ECN: MAP6458DBE/2008496A
• Publishing System: TPAS
• Access date: 12/5/2008
• Document ECN's: Latest Available
Installation and Service—
64058TG1L, TG1R
64058TS1L, TS1R
7272TG1L,TG1R
PELLERIN MILNOR CORPORATION
POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.

Advertisement

Table of Contents
loading

Summary of Contents for Milnor 64058TG1L

  • Page 1 Published Manual Number/ECN: MAP6458DBE/2008496A • Publishing System: TPAS • Access date: 12/5/2008 • Document ECN's: Latest Available Installation and Service— 64058TG1L, TG1R 64058TS1L, TS1R 7272TG1L,TG1R PELLERIN MILNOR CORPORATION POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.
  • Page 2 ECN dates for those documents may be listed in the table of contents. When communicating with the Milnor factory regarding this manual, please also provide the other identifying information shown on the cover, including the publishing system, access date, and whether the document ECN’s are the latest available or exact.
  • Page 3: Table Of Contents

    Table of Contents for MAP6458DBE/2008496A 64058TG1L, TG1R 64058TS1L, TS1R 7272TG1L,TG1R Page Description Document/ECN Limited Standard Warranty BMP720097/2008272A How to Order Parts BMP720097R/72332A Safety—Dryers, Conditioners, and Shakers BIUUUS27/20051111 Safety Placard Use and Placement 64058TG1, TS1L, TS1R 72072TG1,TS1L,TS1R BMP040034/2004313V Safety Placard Use and Placement ISO 6458TG1,TS1L,TS1R...
  • Page 4: Page Description

    Table of Contents, cont. Page Description Document/ECN Gas Schematic and Burner Installation 64058TG1L,TG1R BMP000063/2004405V Gas Schematic and Burner Installation 7272TG1L,TG1R BMP040064/2004405V GSA Gas Piping 6458TG1L,TG1R 7272TG1L,TG1R BMP020008/2004406V Firebox, Burner & Combustion Air BMP070029/2007244B Gas Fire Eye Assembly BMP040067/2007244B Inlet Probe Assembly...
  • Page 5 Table of Contents, cont. Page Description Document/ECN Dimensional Drawing - DRYVAC01 Options BDDRYVA1BB/2001286D...
  • Page 7: Limited Standard Warranty

    (unless the time period is specifically extended for certain parts pursuant to a specific MILNOR published extended warranty) from our factory with no operating hour limitation. This warranty is contingent upon the equipment being installed, operated and serviced as specified in the operating manual supplied with the equipment, and operated under normal conditions by competent operators.
  • Page 9: How To Order Parts

    How to order repair parts Repair parts may be ordered either from the authorized dealer who sold you this machine, or directly from the MILNOR factory. In most cases, your dealer will have these parts in stock. When ordering parts, please be sure to give us the following information: 1.
  • Page 10: Safety-Dryers, Conditioners, And Shakers

    The owner/user must familiarize himself with the contents of all machine instruction manuals. The owner/user should direct any questions about these instructions to a Milnor® dealer or the Milnor® Service department.
  • Page 11 The Safety Guide and other machine manuals must be available at all times to the appropriate personnel. See the machine service manual for safety placard part numbers. Contact the Milnor Parts department for replacement placards or manuals. Maintenance —Ensure the machine is inspected and serviced in accordance with the norms of 1.5.
  • Page 12 They can produce explosive fumes when heated. • Do not use flammable solvents in processing. • Do not load machine with goods containing dry cleaning materials. • Do not use the machine in the presence of solvent fumes. PELLERIN MILNOR CORPORATION...
  • Page 13 • Verify the overheat control system and plant fire extinguishers are functioning before operating the machine. Be sure to turn water supply on after testing. • Keep the manual shut-off test valve open except when testing. • Test or inspect the system after every automatic actuation, or monthly. PELLERIN MILNOR CORPORATION...
  • Page 14 These components move automatically. • Do not service the machine unless qualified and authorized. You must clearly understand the hazards and how to avoid them. PELLERIN MILNOR CORPORATION...
  • Page 15 Hazards include but are not limited to panic, burns, poisoning, suffocation, heat prostration, biological contamination, electrocution, and crushing. • Do not enter the cylinder until it has been thoroughly purged, flushed, drained, cooled, and immobilized. — End of BIUUUS27 — PELLERIN MILNOR CORPORATION...
  • Page 17 BMP040034/2004313V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Safety Placard Placement Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 19 BMP040035/2004313V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Safety Placard Placement Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 22: Guards & Covers 7272Tg1L,Tg1R

    BMP040071/2004441V (Sheet 3 of 3) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Guards & Covers 7272TG1L,TG1R Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 24 BMP020051/2002412V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List— Side Doors Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 26: Side Doors 7272Tg1L,Tg1R

    BMP040071/2004441V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Side Doors 7272TG1L,TG1R Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 27 Do not hesitate to file a claim with the carrier if the machine has been damaged in any way during shipment. Milnor® will be glad to assist you in filing your claim, but is not responsible for shipping damage to the machine once it has been delivered to the carrier in good condition.
  • Page 28 (house and base) skidded separately for shipment. It is occasionally possible to reduce the overall dimensions by removing piping and by other special modifications. Consult the Milnor factory for more information. 2. Provide sufficient clearance around machine for normal operation and maintenance procedures.
  • Page 29 Anchor bolts must not be installed until the machine is on site so that the machine itself may be used to determine precise anchor bolt locations. Consult Milnor if any obstruction prevents the installation of any anchor bolts. Anchor bolts cannot be indiscriminately omitted.
  • Page 30 —Check the interior of the perforated cylinder for smoothness "$ before placing the machine in service. Milnor cannot accept claims for damage to the cylinder's smooth finish after the machine has been placed in service. — End of BIPD6I02 —...
  • Page 41 BMP070009/2007143B (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Optional Unload Bridge Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 42: How To Size Inlet And Discharge Air Ducting

    See the machine dimensional drawing for main air and combustion air scfm requirements. Provided the pressure drop is uniform throughout the entire drying cycle, your MILNOR machine will provide a proper air flow against a maximum total pressure drop of 0.5" (13 mm) water column.
  • Page 43 8. This information is intended to be general in nature and is provided only as a guide. MILNOR accepts no responsibility nor liability resulting from the use of this information. You may find it advisable to employ the services of a professional engineer licensed to practice in your area.
  • Page 44 How to Size Inlet and Discharge Air Ducting Laying Out Ducting (English Units) Select ducting from the following table. Table 1: Data for Sizing Inlet and Exhaust Ducts for Milnor Machines Model Losses in inches of water Rectangular Dimensions (inches)
  • Page 45 3 Pc Round short elbow P. D.(Pressure drop) = 0.18 Transition is considered straight P. D.(Pressure drop) = (15/100) x 0.3 = 0.05 Lint collector - Max allowable P. D.(Pressure drop) = 0.25 — End of BIPDGI01 — PELLERIN MILNOR CORPORATION...
  • Page 47: Section 1: Service And Maintenance

    Section Service and Maintenance...
  • Page 48: Service Connections For Gas, Steam And Hot Oil Dryers, Conditioners And Shakers

    CAUTION 4 : Machine Damage Hazards (Steam Dryers and Conditioners Only)— Allow steam coil to preheat and purge condensate before operating dryer or conditioner. • Verify that the facility boiler has operated at least 15 minutes before the dryer receives the PELLERIN MILNOR CORPORATION...
  • Page 49 CAUTION 6 : Machine Damage Hazards—Steam coil antifreeze is drained at the factory but some residue may remain. • the steam condensate return line should be routed to the sewer for the first hour of operation to prevent residual antifreeze from entering the boiler system. PELLERIN MILNOR CORPORATION...
  • Page 50 Note 2: The horsepower "for sizing boiler" provides for actual consumption and some external energy losses. See “ABOUT THE STEAM AND HOT OIL CONTROL SYSTEMS.”.. (see Table of Contents). Note 3: Ducting to exterior of building highly recommended, but may be left unpiped if laundry always open to outside air. PELLERIN MILNOR CORPORATION...
  • Page 51 3. Locate blower contactor inside the high voltage enclosure. 4. Match tagged coil wires with the tagged contactor coil terminal. Insert wires in terminal then tighten fastener. Figure 1: Blower Shipping Bracket Figure 2: Reconnect Blower Contactor Coil Wires PELLERIN MILNOR CORPORATION...
  • Page 52 Normally the machine stops and water is sprayed into the cylinder if outlet temperature reaches 240 degrees Fahrenheit (116 degrees Celsius). Figure 3: Bumper Guard Installation Where to install bumpers Legend Bumper guards Height determined by user — End of BIPDUI01 — PELLERIN MILNOR CORPORATION...
  • Page 53: Dryer Preventive Maintenance

    Dryer Preventive Maintenance Your machine must be lubricated in strict accordance with the instructions in this section to achieve optimum performance and service life from your Milnor® machine and warranty requirements. WARNING 1 : Entangle and Crush Hazards—Guards, covers, and panels—Operating the machine with any guard, cover, or panel removed exposes moving components.
  • Page 54 If you cannot obtain either the specified lubricant or a valid equivalent locally, contact the Milnor Service Department for assistance. PELLERIN MILNOR CORPORATION...
  • Page 55 Mobile Gear 630 Guide, drive, Check for alignment and wear. If service is Monthly/200 hours (see Figures 2 and 3 and support required, see Milnor dealer. Note 1) rollers Drive chain Clean and grease Monthly/200 hours (see Figure 2, Shell...
  • Page 56 T-seal and T- Check for wear and tight fit. If service is Monthly/200 hours (see Figure 9 seal tension required, see Milnor dealer Note 1) spring Blower vanes Clean out with industrial vacuum Weekly Figure 13 Temperature Check for melted plastic buildup.
  • Page 57 Figure 3: Guide Roller Figure 4: Combustion Air Filter Sock Figure 5: Air Strainer and Filter Figure 6: Rubber Seal at Front of Basket Figure 7: Unload Door Felt Seal Figure 8: Load Door Bottom Felt Seal PELLERIN MILNOR CORPORATION...
  • Page 58 Dryer Preventive Maintenance Figure 9: T-seal and T-Seal Figure 10: Main Air Damper Tension Spring Figure 11: Unload-Door Air Cylinder Figure 12: Temperature Sensors PELLERIN MILNOR CORPORATION...
  • Page 59 Dryer Preventive Maintenance Figure 13: Blower Vanes Figure 14: Rear Support Roller Grease Point Figure 15: Front Support Roller Grease Point Figure 16: Steam coil lint drawer PELLERIN MILNOR CORPORATION...
  • Page 60 Dryer Preventive Maintenance Figure 17: Automatic water sprinkler — End of BIPD6M01 — PELLERIN MILNOR CORPORATION...
  • Page 61: Gas And Air Adjustments

    These ® procedures require manometer kits KWGP030100 and KWGP150100 (available from Milnor or equivalent equipment. Each kit includes a differential pressure gauge, fittings and tubing. Removal of the temperature probe is not normally a part of this procedure. However, in the event that the probe is found to be defective, observe the following caution.
  • Page 62 Although the major steps are the same for each type of flame control, the sub-steps vary somewhat. 3. You will need to refer to both the summarized and the detailed information when testing and adjusting the system. PELLERIN MILNOR CORPORATION...
  • Page 63 Pilot Gas Atmosphere Pressure Pilot Gas Flame Atmosphere Regulated Gas 100 (255 for Pressure Atmosphere models) Regulated Gas Atmosphere Pressure Burner Minimum Inlet Fire temperature High Gas Atmosphere YES/NO YES/NO Pressure Low Gas Atmosphere YES/NO YES/NO Pressure PELLERIN MILNOR CORPORATION...
  • Page 64 Note 2: Set Regulated Main Gas Pressure at 4.5 for NOx controlled dryers Note 3: This data only applies to the older noise suppresion design that used a flexible combustion air duct on the rear of the machine. PELLERIN MILNOR CORPORATION...
  • Page 65 Burner Minimum Fire (above ambient 70-80 F 21-27 C 70-80 F 21-27 C 70-80 F 21-27 C temperature) High Gas Pressure 6.875 6.875 6.875 Low Gas Pressure 2.75 2.75 2.75 Back Pressure Switch Burner Pressure Switch 0.06 0.06 0.06 PELLERIN MILNOR CORPORATION...
  • Page 66 Manual test valve Pilot gas flame valve (Fireye) Modulating gas valve Pilot gas gauge point Pilot gas regulator Main gas regulator Static gas pressure test point Manual gas and pilot gas Gas schematic Gas pressure test points PELLERIN MILNOR CORPORATION...
  • Page 67 Legend Test point 3 located behind the main gas valves Pilot gas valve Pilot gas regulator Main gas regulator Static gas pressure test point Figure 3: Fireye Flame Control Test Jacks (Cover removed for clarity) PELLERIN MILNOR CORPORATION...
  • Page 68 Main air needle valve Main air pressure switch Main air gauge point Landis & Gyr flame control reset Figure 5: Mount manometer horizontally for Figure 6: Modulating gas valve Y combustion air adjustment minimum adjustment PELLERIN MILNOR CORPORATION...
  • Page 69 Figure 7: Pilot gas flame valve (Fireye) Valve details Legend Handle (shown in open position) Cover screw Adjusting screw (CW for less pilot gas, CCW for more pilot gas) Figure 8: Back pressure switch (model AAC and later) PELLERIN MILNOR CORPORATION...
  • Page 70 Manual pilot gas shut-off and regulator Legend Two pilot gas solenoid valves Two pilot gas solenoid valves Pilot gas flame valve (remove and store handle after setting) Pilot gas gauge point Pilot gas regulator GG. Manual pilot gas shut off valve PELLERIN MILNOR CORPORATION...
  • Page 71 Adjustment Procedures for Fireye Equipped Dryers Step 1: Setting Static Gas Pressure 2.1. WARNING 2 : Entangle and Crush Hazard —Moving parts can entangle and crush body parts • Lock out and tag out power before servicing. 1. Turn machine off. PELLERIN MILNOR CORPORATION...
  • Page 72 Resulting display SETUP PROCEDURE Selects “RETURN TO AUTOMATIC” Returns to the run mode WARNING 3 : Entangle and Crush Hazard —Moving parts can entangle and crush body parts • Lock out and tag out power before servicing. PELLERIN MILNOR CORPORATION...
  • Page 73 4) until the manometer is at the value shown in Table 2 Table 3. Slowly rotate the main air pressure switch dial (I, Figure 4) until the status light is on. 4. Close the needle valve fully. PELLERIN MILNOR CORPORATION...
  • Page 74 See “Setting Conditions” under “Adjustment Procedures for Landis and Gyr Equipped Dryers,” for additional information on running manual dry codes, PELLERIN MILNOR CORPORATION...
  • Page 75 1. Put dryer in Setup Mode E, (see "Step 6: Setting Burner Minimum Fire.") 2. Attach the low pressure side of the manometer to the plenum air gauge point (item 2, Figure 10) and leave the other side open to the atmosphere. PELLERIN MILNOR CORPORATION...
  • Page 76 5. Adjust pressure of incoming gas (upstream from dryer) to achieve value listed in the Table 2 Table 3. Incoming gas pressure must be at this value before further adjustments can be made. Pressures exceeding specified range will damage regulator. PELLERIN MILNOR CORPORATION...
  • Page 77 Closes modulating gas valve (position). Hold keys until MVP = & 000. TICHTOC LDA MVP BSPD xxx+xxx x2x xxx xxxx The dryer will continue to fire at (MVP=000) until commanded to return to automatic. Perform the remaining adjustments herein. Upon completion, Returns to automatic. PELLERIN MILNOR CORPORATION...
  • Page 78 4. Close the needle valve fully after setting switch. Step 4A Setting Pilot Gas Pressure 3.5. WARNING 8 : Explosion and Fire Hazard—Pilot Gas pressure/Pilot Gas flame procedure has potential for gas release. • Follow instructions carefully. PELLERIN MILNOR CORPORATION...
  • Page 79 Verify the setting by opening the manual test valve fully, then closing the valve while watching the manometer. The high gas pressure switch should trip when the set value is reached. 3. Reopen manual test valve fully. PELLERIN MILNOR CORPORATION...
  • Page 80 (CSA models), set the modulating valve position to MVP=100 and verify that the regulated main gas pressure is 6.5 inches (165mm) water column. 2. Connect a manometer between the burner gas pipe and the burner box plenum reference point, as shown in Figure PELLERIN MILNOR CORPORATION...
  • Page 81 6. Tighten the locking screw on the adjusting knob to retain the setting. Figure 11: Manometer Connection Points Photograph Legend Burner box plenum manometer connection Gas pipe manometer connection Manometer PELLERIN MILNOR CORPORATION...
  • Page 82 Gas and Air Adjustments Figure 12: On-Off Valve Photograph Legend Valve body Adjusting knob Locking screw — End of BIPDJM01 — PELLERIN MILNOR CORPORATION...
  • Page 83: Removing Lint Buildup From The Combustion

    1 1. Carefully connect the air wand to plant air (see 2. Insert the wand into the access hole in the burner housing (item 3) with the holes in the wand pointing toward the diffuser plate. PELLERIN MILNOR CORPORATION...
  • Page 84: Conditioners

    Internal diffuser plate where holes in plate can collect lint. Flow restrictor plate used on some models 1/2" (13) stainless steel tubing Threaded connector Closed end with three 3/32" (2 mm) holes on same side of tubing. PELLERIN MILNOR CORPORATION...
  • Page 85 For example, you may find that your machine has an air flow restrictor (Figure 3, item 5), which must be removed. Perform this cleaning whenever you clean the diffuser plate. — End of BIPDPM01 — PELLERIN MILNOR CORPORATION...
  • Page 86: Fire Safety System Operation And Maintenance

    “Outlet Temperature Exceeded “What to Do If action the Sprinkler “Error Messages” 220°” Faults” the Sprinkler Actuates” elsewhere. Actuates” * Not applicable to steam dryers ** Not applicable to non-modulating steam dryers. PELLERIN MILNOR CORPORATION...
  • Page 87 Outlet temperature thermocouple location. Provides temperature data to the controller. Sprinkler valve assembly Reset handle Actuation handle Figure 2: View of ST550A, ST550B and T2 Figure 3: View of ST225-1 Figure 4: View of ST225-2 and T3 Figure 5: View of STBB PELLERIN MILNOR CORPORATION...
  • Page 88 2.1, above, if severe enough, can result in sprinkler actuation. Resolve no-fire sprinkler actuations by correcting the cause. Never disable the sprinkler. If a fire should occur, the sprinkler is your first line of defense, and your best defense against a potentially uncontrollable situation. PELLERIN MILNOR CORPORATION...
  • Page 89 Pull the sprinkler reset handle down fully, so that it latches. A11: Reset the sprinkler A12: Open the manual valve CAUTION 3 : Risk of sprinkler failure—The sprinkler manual water valve must be open for the sprinkler to function. Return the dryer to service PELLERIN MILNOR CORPORATION...
  • Page 90 See "Viewing Inputs and Outputs During Operation" in the reference dryer functions manual for more information. STOP and repair by a Damage? qualified technician Remember to return all manual controls to the automatic operation position RETURN the dryer to service — End of BIPDUM01 — PELLERIN MILNOR CORPORATION...
  • Page 91: Felt Seal Inspection And Maintenance

    • Lockout/tagout power at the external disconnect before accessing guide rollers. • Never place fingers in the basket-to-shell front gap. Use only tools. 1. With the dryer empty of goods, prepare for safe entry as follows: PELLERIN MILNOR CORPORATION...
  • Page 92 3M Rubber and Gasket Adhesive #1300, used to glue the felt seals in place is available from Milnor in one pint cans (Milnor P/N 20C044). 1. If replacing the front-most seal, fabricate the tools shown in...
  • Page 93 5, 3, and 2. Before re-installing the flap seal, make sure there are no sharp edges (glue or sharp metal) that could cut the flap seal as it rides against the ring. Use a sander to smooth these down as needed. PELLERIN MILNOR CORPORATION...
  • Page 94 How To Close a Front Seal Gap [Document BIPD6M04] This instruction applies to Milnor dryer models 50040xxx, 6458xxxx and 7272xxxx. The gap between the two felt seals at the front of the basket must not exceed 1/4" (6 mm). These seals help to retain heat and prevent goods from squeezing between the basket and shell front.
  • Page 95: Fastener Torque Requirements

    If fastener torque specifications or threadlocking compound requirements in an assembly document vary from the specifications in this document, use the assembly document. Figure 1: Common Bolts Used in Milnor Equipment Bolt Head Identifying Marks Legend SAE Grades 1 and 2, ASTM A307, and stainless steel...
  • Page 96 Table 3: Torque Values for Plated Fasteners 5/16-inch and Smaller Bolt Grade Grade 2 Grade 5 Grade 8 Grade BC Bolt Size Pound-Inches Pound-Inches Pound-Inches Pound-Inches 1/4 x 20 1/4 x 28 5/16 x 18 5/16 x 24 PELLERIN MILNOR CORPORATION...
  • Page 97 With Threadlocking Compound 1.1.2. Table 5: Threadlocking Compound Selection by Bolt Size Bolt Size LocTite Product 1/4" 1/4" – 5/8" 5/8" – 7/8" 1" + LocTite 222 LocTite 242 LocTite 262 LocTite 272 High temperature LocTite 277 PELLERIN MILNOR CORPORATION...
  • Page 98 Table 8: Torque Values for Applications of LocTite 262 Bolt Grade Grade 2 Grade 5 Grade 8 Grade BC Bolt Size Pound-feet Pound-feet Pound-feet Pound-feet 3/4 x 10 3/4 x 16 7/8 x 9 7/8 x 14 PELLERIN MILNOR CORPORATION...
  • Page 99 Table 11: Torque Values for Stainless Steel Fasteners 5/16-inch and Smaller 18-8 Stainless with 316 Stainless 18-8 Stainless Loctite 767 Nominal Pound- Pound- Pound- Bolt Size Inches Inches Inches 1/4 x 20 1/4 x 28 5/16 x 18 5/16 x 24 PELLERIN MILNOR CORPORATION...
  • Page 100 CAUTION 2 : Malfunction Hazard—Improper application of threadlocking compounds may result in fasteners becoming loose from impact, heat, or vibration. Loose fasteners can cause the equipment to malfunction. • Read and follow the threadlocking compound manufacturer's instructions and warnings. PELLERIN MILNOR CORPORATION...
  • Page 101 No threadlocking compound here Cover this area Nut depth Disassembly —For low-strength and medium-strength products, disassemble with hand tools. 3.3. For high-strength products, apply localized heat for five minutes. Disassemble with hand tools while the parts are still hot. PELLERIN MILNOR CORPORATION...
  • Page 102 Fastener Torque Requirements Figure 4: Disassembly Use Localized Heat Legend Soldering gun heating small fastener Torch heating large fastener — End of BIUUUM04 — PELLERIN MILNOR CORPORATION...
  • Page 103: Section 2: Drive Assemblies

    Section Drive Assemblies...
  • Page 106 BMP000051/2008123B (Sheet 3 of 3) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Drive Chart Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 110 BMP000053/2004441V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Cylinder Installation Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 112 BMP000056/2004401V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—T-Seal Assembly Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 120: Guide Roller Assembly

    BMP970024/2007094B (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Guide Roller Assembly Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 129 BMP040061/2007234B (Sheet 5 of 5) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Bloer & Exhaust Duct Installation Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 131: Section 3: Gas Assemblies

    Section Gas Assemblies...
  • Page 133 BMP000063/04405V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Gas Schematic & Burner Installation Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 136 BMP040064/2004405V (Sheet 3 of 3) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List—Gas Schematic & Burner Installation Find the correct assembly first, then find the needed components. The item letters (A, B, C, etc.) assigned to assemblies are referred to in the "Used In"...
  • Page 149 Section Steam Assemblies...
  • Page 155 Section Pneumatics...
  • Page 167 Section Door Assemblies...
  • Page 177 Section Water Assemblies...
  • Page 179 BMP960031/97017V (Sheet 2 of 2) Pellerin Milnor Corporation Pellerin Milnor Corporation Litho in U.S.A. P. O. Box 400, Kenner, LA 70063-0400 Parts List, cont.—Sprinkler Assembly Description Comments Used In Item Part Number 07 50402 86101BTRIP LINK FOR SPRINKLER 15C060 HXSOKSTRIPBOLT 1/2X3/4W 3/8-16 GR5 54J010 SHFTCOLL #2X568 1/2"ID EA=1PC...
  • Page 183 Section Installation Drawings...

This manual is also suitable for:

64058tg1r64058ts1l64058ts1r7272tg1l7272tg1r

Table of Contents