Installation of outdoor unit

Step 1: fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Take sufficient protective measures when
installing the outdoor unit.
Make sure the support can withstand at least
four times of the unit weight.
The outdoor unit should be installed at least
3cm above the floor in order to install drain joint.
For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.

Step 2: install drain joint

(Only for cooling and heating unit)
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the drain
vent.
drain vent
outdoor drain joint
drain hose
chassis
at least 3cm above the floor
Step 3: fix outdoor unit
1. Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with
bolts.
foot holes