Planning Irf Fabric Setup; Planning Irf Fabric Size And The Installation Site; Identifying The Master Switch And Planning Irf Member Ids - H3C S5830 Series Installation Manual

Hide thumbs Also See for S5830 Series:
Table of Contents

Advertisement

Step
1.
Plan IRF fabric setup.
2.
Install IRF member
switches.
3.
Connect ground wires
and power cords.
4.
Power on the switches.
5.
Configure basic IRF
settings.
6.
Connect the physical
IRF ports.

Planning IRF fabric setup

Planning IRF fabric size and the installation site

Choose S5830 switch models and identify the number of required IRF member switches, depending on
the user density and upstream bandwidth requirements. The switching capacity of an IRF fabric equals
the total switching capacities of all member switches.
Plan the installation site depending on your network solution, as follows:
Place all IRF member switches in one rack for centralized high-density access.
Distribute the IRF member switches in different racks to implement the top-of-rack (ToR) access
solution for a data center.
NOTE:
To increase the switching capacity without any topology change or replacement, you can plug an S5830
switch into an IRF fabric.

Identifying the master switch and planning IRF member IDs

Determine which switch you want to use as the master for managing all member switches in the IRF fabric.
An IRF fabric has only one master switch. You configure and manage all member switches in the IRF
fabric at the command line interface of the master switch.
Description
Plan the installation site and IRF fabric setup parameters. Complete the
following tasks:
Planning IRF fabric size and the installation site
Identifying the master switch and planning IRF member IDs
Planning IRF topology and connections
Identifying physical IRF ports on the member switches
Planning the cabling scheme
See
"Installing the switch in a 19-inch
See
"Grounding the
switch" and
N/A
For more information about IRF, see H3C S5830 Switch Series IRF
Configuration Guide.
Connect the physical IRF ports on the switches. Use SFP+ transceiver modules
and fibers to connect 10-Gigabit SFP+ ports over a long distance, or use SFP+
cables to connect 10-Gigabit SFP+ ports over a short distance.
All switches except the master switch automatically reboot, and the IRF fabric is
established.
35
rack."
"Connecting the power
cord."

Advertisement

Table of Contents
loading

This manual is also suitable for:

S5830-52scS5830-106s