Garmin GI 275 Maintenance Manual page 59

Attitude indicator
Hide thumbs Also See for GI 275:
Table of Contents

Advertisement

If error self clears, perform
battery rundown test, then
fully charge battery, ensure
190-02246-11
Rev. 1
Battery operation
Battery operation
warning
warning
Maintenance
Maintenance
Log Message
Log Message
Battery overcurrent
Battery overcurrent
during charge
during discharge
protection fault
protection fault
Cause
Cause
Battery circuitry
Battery short circuit
failure
failure
GI 275 charging
GI 275 charging
circuitry failure
circuitry failure
Corrective
Corrective
Action
Action
If error self clears, perform
battery rundown test, then
fully charge battery, ensure
alert does not reoccur
alert does not reoccur
Replace battery
Replace battery
Return GI 275 to
Return GI 275 to
Garmin for service
Garmin for service
Figure 4-16 Battery Alert Message Troubleshooting
Battery Alert 
Messages Cont'd
Battery warning:
Charge inhibited
Maintenance
Log Message
Battery cell
overvoltage
protection fault
Cause
Battery circuitry
failure
GI 275 charging
circuitry failure
Corrective
Action
If error self clears, perform
battery rundown test, then
fully charge battery, ensure
alert does not reoccur
Replace battery
Return GI 275 to
Garmin for service
Sheet 2 of 4
Battery warning:
Charge inhibited
Maintenance
Log Message
Battery cell
undervoltage
protection fault
Cause
Battery charge was
low and left to
discharge further
Corrective
Action
Ensure battery warmed to
room temperature
environment, attempt
charging
Replace battery
If fault persists, 
contact Garmin.