Trane GVAF Series Installation Operation & Maintenance page 32

R134a-r1234ze-r513a air cooled high speed centrifugal chiller
Table of Contents

Advertisement

Optional Free-Cooling
With a Phillips screwdriver, move the end of travel. Fix
it to always keep an opening between 100% and the
minimum desired (50%) in example below.
FWD
Power supply
Capacities
Cooling capacity on water (1)
Heating capacity on water (2)
Fan motor
Fan power input (3)
Current amps (3)
Start-up amps
Air flow
minimum
nominal
maximum
Main coil
Water entering/leaving connections
Electric heater (accessory for blower only)
Electric power supply
Heating capacity
Hot water coil (accessory for blower only)
Heating capacity (4)
G2 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
G4 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
Condensate pump (accessory)
Water flow - lift height
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5)
Sound power level (5)
Unit dimensions
Width x Depth
Height
Shipped unit dimensions
Width x Depth
Note for maintenance : Check glycol circuit pressure before free cooling operation season starts. Run glycol pump
Height
few minutes in manual override during monthly maintenance operation when free cooling is continuously OFF to
Weight
Colour
avoid possible glycol cristalization. Pump Override function is located in TD7 via Button Settings -> Manual Control
Recommended fuse size
Settings -> Free Cooling Pump Override.
Unit alone (aM/gI)
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
4
32
Technical Data
If the minimum opening is modified after the first
powering, motor re-calibration is needed to validate the
new operating range. When motor is powered, push
green led button (2). Motor memorizes the new reference
08
of end of travel position on its signal (2...10 VDC)
(V/Ph/Hz)
(kW)
5,2
(kW)
6,3
(type)
(kW)
0,23
(A)
1,1
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
20
230/1/50
8,3
15
11,9
18,9
2 x direct drive centrifugal
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
486x271x8
586x321x8
2
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
350
1133 x 754
1333 x 864
310
360
46
61
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
CTV-SVX009D-GB