Trane GVAF Series Installation Operation & Maintenance page 19

R134a-r1234ze-r513a air cooled high speed centrifugal chiller
Table of Contents

Advertisement

Evaporator Piping Components
Piping components include all devices and controls used to provide proper water system operation and unit operating
safety. A typical GVAF evaporator piping is shown below.
Sound power levels
Figure 5 – Typical GVAF evaporator water piping
Discharge
5
4
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan
Unit
speed
7
1
FWD 08
2
3
1
FWD 10
2
3
1
FWD 12
2
3
1
FWD 14
2
3
1
FWD 20
2
3
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
1 = Isolation valve
Fan
2 = Vibration isolators
Unit
speed
3 = Evaporator – End view (2-pass)
1
4 = Evaporator Waterbox
FWD 08
2
3
5 = Vent
1
6 = Strainer
FWD 10
2
7 = Drain
3
1
Entering Chilled Water Piping
FWD 12
2
3
1
• Air vents to bleed the air from the system (to be placed
FWD 14
2
on the highest point)
3
• Water pressure gauges with shutoff valves
1
FWD 20
2
• Vibration eliminators
3
• Shutoff (isolation) valves
• Thermometers if desired (temperature readings
available on chiller controller display)
• Clean-out tees
• Pipe strainer
CTV-SVX009D-GB
UNT-PRC002-GB
3
Power level in dB(A), per Hz frequency band
6
125
250
500
B
55
50
42
57
54
47
58
57
50
57
51
45
58
54
48
60
58
1
50
57
51
45
58
54
48
60
58
50
56
62
50
61
66
55
63
69
58
57
63
51
1
61
66
55
7
C
63
69
58
Power level in dB(A), per Hz frequency band
125
250
500
56
55
55
63
62
60
66
65
63
62
58
55
66
63
60
70
67
63
62
58
55
66
63
60
70
67
63
66
65
65
73
72
69
78
76
73
68
72
64
76
76
68
78
79
71
1000
2000
2
37
37
40
30
42
32
42
34
45
38
48
40
42
34
45
38
48
40
48
39
53
47
56
50
49
40
53
47
56
50
2
Pi = Pressure gauge
FT = Water Flow Switch
1000
2000
T1 = Evaporator Water Inlet Temperature Sensor
53
46
T2 = Evaporator Water Outlet Temperature Sensor
60
53
62
56
A = Isolate unit for initial water loop cleaning
58
51
B = Vent must be installed at the high point of the line
62
56
C = Drain must be installed at the low point of the line
65
59
58
51
Leaving Chilled Water Piping
62
56
65
59
65
57
• Air vents to bleed the air from the system (to be placed
71
64
on the highest point)
75
69
• Water pressure gauges with shut off valves
64
56
71
65
• Vibration eliminators
74
69
• Shutoff (isolation) valves
• Thermometers (temperature readings available on the
chiller controller display)
• Clean-out tees
• Balancing valve
• Flow Proving Device
Evaporator Piping
Overall power
4000
8000
dB(A)
1
A
31
30
46
38
40
50
40
43
53
33
28
48
39
35
51
42
39
54
33
28
48
39
35
51
42
39
54
38
36
56
46
45
60
50
49
63
39
37
57
46
45
60
1
50
49
63
A
Overall power
4000
8000
dB(A)
45
42
57
53
53
64
55
57
67
48
44
61
55
52
66
59
57
69
48
44
61
55
52
66
59
57
69
50
46
68
59
57
74
64
63
78
52
50
69
61
61
75
66
66
78
11
19