Repair
Transformer Primary Check
1. Turn main power OFF
2. Locate the two smaller (10 AWG) wires coming out
of transformer. Trace these wires back to contactor
and circuit breaker (811). Use an ohmmeter to test
for continuity between two wires; there should be
continuity.
Transformer Secondary Check
1. Turn main power OFF
2. Locate the two larger (6 AWG) wires coming out of
transformer. Trace these wires back to large green
connector under hose control module and circuit
breaker (809). Use an ohmmeter to test for
continuity between two wires; there should be
continuity.
If you are not sure which wire in green plug under
hose module connects to transformer, test both
wires. One wire should have continuity with the
other transformer wire in breaker (809) and the
other wire should not.
809
811
F
. 12 Circuit Breaker Module
IG
40
.
.
3. To verify transformer voltage, turn on hose zone.
Measure voltage from 18CB-2 to
POD-HOSE-P15-2; see Reactor Electrical
Diagrams manual.
Model
310 ft.
410 ft.
* For 230 Vac line voltage.
Replace Transformer
NOTE: Use this procedure to replace transformer.
1. Turn main power OFF
supply.
2. Open Reactor cabinet.
3. Remove bolts holding transformer to cabinet floor.
Slide transformer forward.
4. Disconnect the transformer wires; see Reactor
Electrical Diagrams manual.
5. Remove transformer from cabinet.
6. Install new transformer in reverse order.
Secondary Voltage
90 Vac*
120 Vac*
. Disconnect power
312063Z