Repair instructions
9
Fit the sleeve in the lower shaft.
Thread the cabling through the lower shaft.
Turn the cabling through 180° so it is fixed in the
sleeve and screw it on loosely with a screw.
See figure 42.
10
Assemble the lower clamp on the outer shaft.
Tighten the two clamps with 5-10 Nm.
See figure 43.
11
Press the cabling into the connector. Make sure
the wings on both sides of the connector are pro-
truding slightly so they hook onto the sides of the
connector.
See figure 44.
12
Assemble the shaft in the battery housing using the
clamp and its screws.
See figure 45.
13
Assemble the connector in the control unit.
14
Assemble the shaft onto the saw head, 2 screws.
15
Couple the cables to a connector and couple the
connector to the motor.
Assemble the cable guard.
See figure 46.
16
Assemble the chain and bar as described in
"6.6 Chain and bar".
Fig 42
Fig 43
Fig 44
Fig 45
Fig 46A