Identification; Zone 1 With Ex Db Iic Gb Type Of Protection (Flameproof Enclosure "D" For The Machine) - Siemens SIMOTICS XP 1MB155 Operating Instructions Manual

Low-voltage motors
Table of Contents

Advertisement

Description
3.3 Design
Note
Further documents
Observe all of the other documents provided with this machine.
Supplementary devices
Depending on the order, various supplementary devices can be installed or mounted. These
include sensors for bearing temperature monitoring or winding monitoring, for example.
Risk of explosion during operation due to too high surface temperature
This can result in death, serious injury, or material damage.
• Prevent the maximum surface temperature from being exceeded by maintaining the
specified operating conditions.
• Monitor the coil temperature. Use the temperature sensor that is built into the stator
winding for this as specified on the rating plate or extra rating plate.
3.3.8

Identification

3.3.8.1

Zone 1 with Ex db IIC Gb type of protection (flameproof enclosure "d" for the machine)

0158
28
DANGER
II
2
CE - or EAC marking
Identification number or name of nominated testing agency
Code for prevention of explosions
Device group: II not for mines susceptible to firedamp, but other hazardous zones
Device category: 2 for occasional danger and for use in Zone 1
Atmosphere: G for gas
Explosion protection: International
Type of protection: "db" flameproof enclosure of machine for a high level of protection
Explosion group: IIC for acetylene
Temperature class: T4 for maximum surface temperature of 135° C
Device protection level: Gb for a high level of protection in hazardous zones with explo-
sive gas mixtures
G
Ex
db
Operating Instructions, 03/2018, A5E41926185A
IIC
T4
Gb
1MB155 / 1MB555