Static Charging When Cleaning; Inspections In The Event Of Faults; First Inspection - Siemens SIMOTICS XP 1MB155 Operating Instructions Manual

Low-voltage motors
Table of Contents

Advertisement

Maintenance
9.1 Inspection and maintenance
9.1.2

Static charging when cleaning

Risk of explosion due to static charging
If you clean the motor, plastic components may become statically charged and ignite a
potentially explosive atmosphere. An explosion can occur. This can result in death, serious
injury or material damage.
● When cleaning ensure that there is absolutely no explosive atmosphere present.
● Clean the plastic parts and components so that absolutely no static charging occurs
● Do not use compressed air for cleaning.
9.1.3

Inspections in the event of faults

Natural disasters or unusual operating conditions, such as overloading or short circuit, are
faults that overload the machine electrically or mechanically.
Immediately perform an inspection after such faults.
9.1.4

First inspection

● Check after approx. 500 operating hours, but after not more than one year:
(*) You can perform these checks while the motor is at standstill or, if required, while running.
● Further checks may be required if so specified in operating instructions of components or
in accordance with the plant-specific conditions.
● If you find any deviations during the inspection, you must rectify them immediately. They
may otherwise damage the motor.
110
Check
The electrical parameters are maintained.
The permissible bearing temperatures are not exceeded.
The smooth running characteristics and machine running noise have not
deteriorated.
The foundation has no cracks or indentations. (*)
When the
motor is
running
X
X
X
X
Operating Instructions, 03/2018, A5E41926185A
At stand-
still
X
1MB155 / 1MB555

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics xp 1mb555

Table of Contents