4 Installation and Commissioning
No.
Disable the option "DHCP".
3.
Enter the network setting from
Figure 4-1
IP address: 192.168.0.2
Subnet mask = 255.255.255.0
"Default gateway" is irrelevant.
Select "Auto negotiation" in the
Ethernet parameters to
automatically determine the speed
transmission.

Downloading the HMI project part into the KTP900 Basic

Connect your PG/PC to the HMI either directly or using the CSM1277 switch.
Table 4-10
No.
Select the operator panel folder "HMI_1
1.
[KTP900 Basic PN]".
Click the "Download to device" button to
download the HMI project part into the
KTP900 Basic.
When the "Extended download to device"
2.
window opens, select "PN/IE" as the type
of the PG/PC interface. "PN/IE".
Select the network card you are using as
the PG/PC interface.
Controlling several fans (ebm-papst) via Modbus RTU
Entry ID: 109476801,
V2.0,
Action
for the HMI:
Action
09/2018
Remarks
Remarks
35