Omron SYSMAC FH Series User Manual page 253

Vision sensor vision system
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Problem
An "Illegal function call" error
sometimes occurs when search
process unit measurement is
executed with the MeasureProc
function
Vision System FH/FZ5 Series
User's Manual (Z340)
Cause
It is possible that no objects
were found in the search
process.
WWW.NNC.IR
Action
An "Illegal function call" error occurs if there are 0
detections in the measurement process of the search
process unit executed with the MeasureProc function.
Use the Try - Catch - End Try function to create a
process that handles the occurrence of 0 detections in
the program.
Reference:
Try - Catch - End Try function (p.773)