Troubleshooting
The indoor unit installation option are set to 020000-100000-200000-300000 by default.
Set the indoor unit option by wireless remote controller. When entering Address option, connect remote
controller receiver.
SEG1
0
SEG7
Using of drain
1
SEG13
Use of external
2
SEG19
Individual
3
control with
remote control
• Even if you set the Use of drain pump (SEG8) option to 0, it is automatically set to 2
(the drain pump is used with 3 minute delay).
• If you set the Maximum filter usage time (SEG18) option to a value other than 2 and 6,
it is automatically set to 2 (1000 hours).
• If you set an option to a value that is out of range specified above, the option is automatically set to 0 by default.
• The external output of SEG15 is generated via MIM-B14 connection. (Refer to the manual of MIM-B14.)
• If you set the Individual control with remote control (SEG20) option to a value other than 0 to 4,
it is automatically set to 0 (Indoor 1).
4-14
SEG2
SEG3
2
Reserved
SEG8
SEG9
Reserved
pump
SEG14
SEG15
Setting the
output of
control
external control
SEG20
SEG21
Heating setting
compensation
offset
SEG4
Use of external
Use of central
temperature
control
sensor
SEG10
Reserved
Reserved
SEG16
S-Plasma ion
Buzzer Control
SEG22
SEG23
The lowest
limit of outdoor
Motion detection
temperature
sensor
for heating
operation
SEG5
SEG6
Compensation of
the fan RPM
SEG11
SEG12
Remote control
SEG17
SEG18
Hours of filter
usage
SEG24
Reserved