Hydraulic tank kit for greensmaster 3120 or 3150 2-wheel drive traction unit

Advertisement

1. Plug
6.
Position the hydraulic tank onto the machine
frame and ensure that the clearance between
the hydraulic tank and the fuel tank is 3.2 to 9.5
mm (1/8 to 3/8 inch).
7.
Apply anti-seize lubricant to the threads of the
3 capscrews. Secure the hydraulic tank to the
machine frame with 3 capscrews, flat washers,
and bushings. Torque the capscrews from 3.4 to
6.7 N∙m (30 to 60 in-lb).
8.
Using your notes taken during the removal of
the existing tank, connect the hydraulic hoses to
the tank fittings. Tighten the hose connections.
9.
Greensmaster 3150 machines: Connect the
machine wire harness to oil-level sensor.
5
Installing the Leak-Detector
Tank
Greensmaster 3150 Machines Only
No Parts Required
Procedure
1.
Position the leak-detector tank onto the hydraulic
tank.
2.
Use the capscrews and the lock washers to
secure the solenoid-valve assembly to the
hydraulic tank
3.
Connect the overflow hose to the hydraulic-tank
spout and secure it with a hose clamp.
4.
Position the carbon canister and bracket onto
the leak-detector tank.
5.
Perform the following steps to secure the
leak-detector tank to the hydraulic tank:
Figure 4
2. Spout
A.
Apply anti-seize lubricant to the threads of
the capscrews.
B.
Use the capscrews, flat washers, neoprene
washers, and spacers to secure the
leak-detector tank and carbon canister to
the hydraulic tank.
C.
Torque the capscrews to 3.4 to 6.7 N∙m (30
to 60 in-lb).
Important:
g229104
capscrews. If you overtighten the screws,
the threads in the hydraulic tank may
become damaged.
6.
Connect the leak-detector-solenoid coil to the
machine wire harness.
7.
Secure the pump-inlet hose to the hydraulic
pump with a hose clamp; refer to
6
Completing the Installation
No Parts Required
Procedure
1.
Fill the hydraulic tank with new hydraulic fluid;
refer to your machine Operator's Manual.
2.
If your machine is equipped with a leak-detector
tank:
A.
Connect the oil-level-sensor wire connector
to the machine wire harness.
B.
Connect the battery; refer to your machine
Operator's Manual.
C.
Ensure that the leak-detector system is
operating; refer to your machine Operator's
Manual
3.
Use the dipstick to monitor the hydraulic-fluid
level.
Note:
As air is removed from the hydraulic
circuit, you may need to adjust the hydraulic-fluid
level after you initially fill the tank.