Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Your new White-Rodgers 5-Day/1-Day/1-Day Digital Thermo-
stat uses the technology of a solid-state microcomputer to
provide precise time/temperature control. This thermostat offers
you the flexibility to design heating and cooling programs that fit
your needs.
Features:
• 24 Volt System powered.
• Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun) pro-
gramming with four separate time/temperature settings per day
• Simultaneous heat and cool program storage
• Preprogrammed temperature control
• Backlit display
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
CAUTION
!
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
ELECTRICAL DATA
Electrical Rating:
18 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
Programmable Electronic Digital Thermostat
OPERATION INSTRUCTIONS
• LCD continuously displays set point, and alternately dis-
plays time and room temperature
• Temperature override until next program period
• Manual program override (HOLD temperature)
• Temporary HOLD
• °F/°C convertibility
• Temperature range 45° to 90°F
• RC, RH, C, W, Y, G , O and B terminals
• B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
• Program storage in case of power loss.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.
APPLICATIONS
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems (no auxiliary heat)
DO NOT USE WITH:
Millivolt systems
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
Printed in U.S.A.
1F80-241
INSTALLATION AND
DESCRIPTION
PRECAUTIONS
WARNING
!

SPECIFICATIONS

PART NO. 37-6313A
0144

Advertisement

loading

Summary of Contents for White Rodgers 1F80-241

  • Page 1: Specifications

    -4°F to 150°F WHITE-RODGERS EMERSON ELECTRIC CO. 9797 REAVIS ROAD ST. LOUIS, MISSOURI 63123-5398 www.white-rodgers.com 1F80-241 Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS • LCD continuously displays set point, and alternately dis- plays time and room temperature • Temperature override until next program period •...
  • Page 2: Check Thermostat Operation

    INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
  • Page 3: Wiring Diagrams

    Heating Relay System Figure 2. Typical wiring diagram for heat only, 3-wire, single transformer systems with common connection (required) Cooling System Relay Figure 3. Typical wiring diagram for cool only, 3-wire, single transformer systems with common connection (required) NOTE RED jumper wire (provided with thermostat) must be connected between thermostat RH and RC terminals for proper thermostat operation with this system.
  • Page 4: Configuration Menu

    TIME PRGM HOLD MO TU WE TH FR Figure 8. Thermostat display, buttons, and switches FAN switch (ON, AUTO). SYSTEM switch (COOL, OFF, HEAT). The Display Indicates day of the week. Flame icon ( ) is displayed when the SYSTEM switch is in the HEAT position.
  • Page 5: Operating Features

    4) Select Energy Management Recovery OFF or ON - Energy Management Recovery (EMR) causes the thermo- stat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint.
  • Page 6: Check Your Programming

    2. Press and hold either hour and AM/PM designation (AM begins at midnight; PM begins at noon). 3. Press TIME once. The display window will show the minutes only. EXAMPLE: 4. Press and hold either minutes. 5. Press TIME once. The display will show the day of the week. 6.