White Rodgers 1F80-240 Installation And Operation Instructions Manual

White Rodgers 1F80-240 Installation And Operation Instructions Manual

Programmable electronic digital thermostat

Advertisement

Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Your new White-Rodgers 5-Day/1-Day/1-Day Digital Thermo-
stat uses the technology of a solid-state microcomputer to
provide precise time/temperature control. This thermostat offers
you the flexibility to design a heating program that fits your needs.
Features:
• Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun) pro-
gramming with four separate time/temperature periods per day
• Preprogrammed temperature control
• LCD continuously displays set point, and alternately dis-
plays time and room temperature
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
(for HEATING ONLY systems)
Programmable Electronic Digital Thermostat
OPERATION INSTRUCTIONS
• Heat program storage
• Backlit display
• Temperature override until next program period
• Manual program override (HOLD temperature)
• Temporary HOLD
• °F/°C convertibility
• Temperature range 45° to 90°F
• RH, W, and G terminals
• Battery powered
• 2 "AA" Energizer
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.
APPLICATIONS
For use with:
• Standard heat only systems
• Electric heat systems
• Gas or oil fired systems
• Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
• Hydronic (hot water or steam) systems
• Single-stage heat pump systems (no auxiliary heat)
• Millivolt systems
DO NOT USE WITH:
• Multi-stage systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems
• Heat pump systems
Printed in U.S.A.
1F80-240
INSTALLATION AND
DESCRIPTION
®
alkaline batteries included
PRECAUTIONS
WARNING
!

SPECIFICATIONS

PART NO. 37-6325B
0148

Advertisement

Table of Contents
loading

Summary of Contents for White Rodgers 1F80-240

  • Page 1: Specifications

    Shipping Temperature Range: -4°F to 150°F WHITE-RODGERS EMERSON ELECTRIC CO. 9797 REAVIS ROAD ST. LOUIS, MISSOURI 63123-5398 www.white-rodgers.com 1F80-240 (for HEATING ONLY systems) Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS • Heat program storage • Backlit display • Temperature override until next program period •...
  • Page 2: Battery Location

    INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermo- stat and the wall mounting plate as an assembly.
  • Page 3: Heating System

    THERMOSTAT SYSTEM Heating System 24 VAC TRANSFORMER Figure 2. Typical wiring diagram for heating only, 2-wire, single transformer systems THERMOSTAT SYSTEM Heating System TRANSFORMER Figure 3. Typical wiring diagram for heating only, 2-wire, single transformer systems Thermostat 3-wire Series 10 Primary Control (located at furnace) Add jumper wire...
  • Page 4: Operation

    OPERATION Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. Your thermostat con- sists of two parts: the thermostat cover and the base. To remove the cover, pull it straight out from the base.
  • Page 5: Operating Features

    Step Press Button(s) Displayed (Factory Default) PRGM and RUN HOLD* HOLD* HOLD* HOLD* HOLD* HOLD* HOLD* * Press HOLD to advance to next item or TIME to move backwards to previous item 4) Select Energy Management Recovery OFF or ON - Energy Management Recovery (EMR) causes the thermo- stat to start heating early to make the building temperature reach the program setpoint at the time you specify.
  • Page 6: Entering Program

    Planning Your Program Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your needs, simply press the RUN button to begin running the factory preset program. If you want to change the preprogrammed times and tempera- tures, follow these steps.
  • Page 7: Troubleshooting

    Symptom No Heat/No Fan (common problems) No Heat Heat or Fan Runs Constantly Furnace Cycles Too Fast or Too Slow (narrow or wide temperature swing) Thermostat Setting and Thermometer Disagree Thermostat Does Not Follow Program Blank Display and/or Keypad Not Responding Reset Operation If a voltage spike or static discharge blanks out the display or...
  • Page 8 For additional product information, visit www.white-rodgers.com...