Typical System Wiring Table - White Rodgers 50A55-843 User Manual

Universal integrated furnace control
Table of Contents

Advertisement

50A55
TERMINAL
TERMINAL
W
G
Terminal
R
block with
Y
captive
screws
C
TWIN*
MV (2 terminals)
TR
TH
RO1
RO2
12-pin
FP
connector
PS
& harness
HLI
HLO
GND
(unused terminal)
IND
4-pin
IGN
connector
IND N
& harness
IGN N
COOL
spade terminal
HEAT
spade terminal
PARK (2 terminals)
spade terminal
LINE
spade terminal
XFMR
spade terminal
EAC (optional)
spade terminal
HUM (optional)
spade terminal
CIR N
spade terminal
LINE N
spade terminal
XFMR N
spade terminal
EAC N (optional)
spade terminal
HUM N (optional)
spade terminal
* The twinning feature is available only on models with six screw terminals; one of these terminals
will be designated "TWIN". All 50A55-843 controls used in twinning applications must have the
"TWIN" terminal.
Maximum recommended flame probe wire length is 36 inches.

TYPICAL SYSTEM WIRING TABLE

TYPE
low voltage thermostat W terminal (or equivalent)
low voltage thermostat G terminal (or equivalent)
low voltage thermostat R terminal (or equivalent)
low voltage thermostat Y terminal (or equivalent)
(2nd wire from Y terminal goes to 24 VAC HOT side of
compressor contactor coil)
24 VAC COMMON side of compressor contactor coil
one wire twinning terminal
gas valve (both gas solenoids are connected in parallel)
24 VAC transformer (low voltage COMMON side)
24 VAC transformer (low voltage HIGH side)
rollout switch OUTPUT
rollout switch INPUT
flame sensor probe*
pressure switch INPUT
high limit INPUT
high limit OUTPUT
MUST BE RELIABLY GROUNDED TO CHASSIS
inducer HOT side
ignitor HOT side
inducer NEUTRAL side
ignitor NEUTRAL side
circulator blower COOL SPEED terminal
circulator blower HEAT SPEED terminal
unused circulator blower terminals
input voltage (120 VAC) HOT side
24 VAC transformer line voltage HOT side
electronic air cleaner HOT side
humidifier HOT side
circulator blower NEUTRAL terminal
input voltage (120 VAC) NEUTRAL side
24 VAC transformer line voltage NEUTRAL side
electronic air cleaner NEUTRAL side
humidifier NEUTRAL side
SYSTEM COMPONENT
CONNECTION