GEM-MFI SERIES
Clean the air cooled condenser:
Air flow on this model is from front to back, so the inside of the ice machine will have to be available to clean
the air cooled condenser. Use a vacuum cleaner or coil cleaner if needed. DO NOT use a wire brush.
● Disconnect electrical power, and remove the air filter if applicable. The filter may be cleaned or replaced.
● Clean the condenser: the condenser may appear to be clean on the surface, but it can still be clogged
internally. Check with a flashlight from the front to see if light can be seen through the condenser fins.
GEM0956 (For Reference)
Step 1. Remove the Top Panel
Step 2. Remove two screws
and unplug fan motors.
Step 3. Pull fan motor assembly
up and to the right to
remove.