Brake Unit - Delta HES Series Instructions For Use Manual

Hybrid energy saving system
Hide thumbs Also See for HES Series:
Table of Contents

Advertisement

Appendix B Optional AccessoriesHES Series
B-6 Brake Unit
Individual Parts and Function Explanation
VFDB-4030/4050 Series
Set voltage as indicated on
the left.
Default is 460V.
Wiring of brake unit and motor drive:
CHARGE
Slave
output/input
Power lamp
Terminal
Choose
"SLAVE"
SLAVE
MASTER
MASTER/SLAVE
Setting Jumper
Alarm output terminals
Input Voltage Setup
Pin
Activated Loop
Terminal
Fault Loop Terminal
Power Input Terminal
+(P) -(N)
,
Input Voltage Setup
480V
460V
440V
415V
400V
380V
Input voltage setting for VFDB-2015/2022/4030/4045
ACT
ERR
The position of the External Terminals
Braking lamp
Fault lamp
------
480V
240V
575V
460V
230V
------
440V
220V
------
415V
210V
------
400V
200V
------
380V
190V
M1:
SLAVE output signal +
M2:
SLAVE output signal -
S1:
SLAVE input signal +
S2:
SLAVE input signal -
NOTE: Please use shielded wires
while wiring.
RC
Brake Resistance
Terminal
B1, B2
CHARGE ACT
Power
Brake Action
Indicator
Indicator
240V
230V
VFDB-2015/2022 Series
220V
Set voltage as indicated
210V
on the right
200V
Default is 230V.
190V
RB
MCM
SON RES
RA
MO1 MO2
EMG MI3
B-16
ERR
Fault
Indicator
DCM
+E24V
Sink/Source
Mode Switch Terminal
MI4
COM
+10V
PI
QI
AUI
MI5
AFM1
AFM
+24V
PO
SW100
V
I
ACM
ACM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents