Viessmann Vitocal 300-G Installation And Service Instructions Manual page 159

Table of Contents

Advertisement

Specification
(cont.)
Type WWC 301.A
Electrical values, heat
pump
Rated voltage, compressor
Rated current, compressor
Starting current, compres-
sor
(with starting current limiter,
not in type BW/BWS/BWC
301.A06)
Starting current, compressor
with stalled armature
Compressor fuse
Protection class
Electrical values, control
unit
Rated voltage
Fuse protection
Fuses
Max. power consumption
Power consumption in oper-
ation
Refrigerant circuit
Refrigerant
Fill volume
Compressor
Permiss. operating pres-
sure
Primary circuit
Secondary circuit
Dimensions
Total length
Total width
Total height (programming
unit open)
06
08
3/N/PE 400 V/50 Hz
A
5.5
6.0
A
25.0
14.0
A
26.0
35.0
A
C16A
B16A
3-pole
3-pole
1/N/PE 230 V/50 Hz
2 x 6.3 AH slow/250 V
W
W
kg
1.55
1.9
Type
bar
bar
mm
mm
mm
Specification
10
13
8.0
10.3
20.0
22.0
48.0
51.5
B16A
B16A
3-pole
3-pole
I
B16A
1000
5
R 410 A
2.2
2.6
Hermetic scroll
28
43
844
600
1155
17
15.0
25.0
75.0
C20A
3-pole
3.5
159