Specification
Specification
(cont.)
Type BW 301.A/BWS 301.A
Connections
Primary flow and return
Heating flow and return
Weight
Heat pump stage 1 (type
BW 301.A)
Heat pump stage 2 (type
BWS 301.A)
Sound power level at
B0/W35 °C
(test with reference to DIN
EN ISO 9614-2)
Type WW 301.A/BWS 301.A in con-
junction with "conversion kit for
water/water heat pump"
Output data to DIN EN 14511 (W10/
W35 °C, 5 K spread)
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance ε
(COP)
Brine (primary circuit)
Content
Min. flow rate (spread 4 K)
Pressure drop (at min. flow
rate)
Max. flow temperature
Min. flow temperature
Heating water (secondary
circuit)
Content
Min. flow rate (spread 10 K) l/h
Pressure drop (at min. flow
rate)
Max. flow temperature
154
06
08
G
G
kg
113
117
kg
109
113
dB(A)
40
41
06
08
kW
7.96
10.46
kW
6.73
8.87
kW
1.32
1.71
6.03
6.11
l
3.0
3.4
l/h
1530
2000
mbar
84
91
°C
25
25
°C
-5
l
2.4
2.9
690
900
mbar
27
36
°C
60
60
10
13
129
135
125
131
41
41
10
13
13.09
17.29
11.09
14.74
2.15
2.74
6.10
6.31
4.0
4.5
2570
3300
98
129
25
25
-5
-5
-5
3.4
4.0
1170
1450
41
49
60
60
17
148
144
42
17
22.69
19.09
3.87
5.87
5.9
4450
143
25
-5
5.2
1990
58
60