G. CONTROL
WIRING
!. Connect
wiring
between
indoor
unit,
outdoor
unit and
thermostat.
The use of color-coded
low-voltage
wires
is recommended.
2. A low voltage terminal
board is provided for control
wiring, and is located on the left side of the cross
brace in the center of the unit.
3. Field wiring diagrams
are provided which show the
low voltage wiring hook-up for a single speed
cooling only system (with supplementary
heaters)
and
a heat pump system (with supplementary
heaters).
Plug in type electrical connectors are provided for use
with supplementary
heaters.
IMPORTANT:
When supplementary
heaters are installed, inspect to insure
that all packaging
material has been removed.
NOTE:
Direct drive motors
have bearings
which are perma-
nently
lubricated
and under normal
use lubrication
is not
recommended.
H. CHECKOUT
PROCEDURE
!. Check
the Air Handler
operation
and installation
in
accordance
with this instruction
on page
12,
2, "Operational
Procedure"
for the system
installation
can be found in the outdoor
unit installer
guide and
will be compatible
with this Air Handler.
Cardboard
packing
material
must be removed
from
inside the blower assembly
before starting
the unit.
Failure to do so may cause indoor blower
motor
failure.
T'STAT
J
[Z]
[Z]
[Z]
%
%
[]
4TEP3F AIR HANDLER
WITH HEAT PUMP
AIR
_NOTE
5
HANDLER
[Z]
[]
i
i
i
%
SEE NOTE 2
IPF_:],,,,/PM-A
SUPPL
HTR.
]
CONTROL BOX
RED
FOR
/3
PH
J
ODT"
I
ODT-2
NOTE3
NOTE 4
TO POWER SUPPLY
PER LOCAL CODES &
AS DEFINED
IN
FIELD
WIRING
TABLE
HEAT PUMP
O.D.
SECTION
(SINGLE
SPEED)
_--R
_--.y
_--0
BR/X2
OR BK
___
BR(T
I
IlIP
f
|
H
|
H
TO POWER SUPPLY __
PER LOCAL CODES
NOTES:
I.
LOW VOLTAGE WIRING
TO BE NO.
18 A.W.G.
MINIMUM CONDUCTORS.
WHEN FIELD-INSTALLED
HEATERS ARE
USED,
DISCARD POWER LEADS WITH
POLARIZED
PLUG I-PM
AND CONNECT
I-PF
TO MATING PLUG
iN THE HEATER
CONTROL BOX AS SHOWN.
3.
IF
OUTDOOR THERMOSTAT(ODT) IS
NOT USED, CONNECT Wl TO W2 TO W3
ON LVTB.
4.
CONNECT IN THIS
MANNER IF
O.D.
UNIT
HAS "F"
CONNECTION.
5.
SEE HEATER WIRING
DIAGRAM FOR
HEATING
ANTICIPATOR
SETTINGS.
INTER-COMPONENT
WIRING
-24
V.
FACTORY
= LINE v.jWIRING
24 V
)FIELD
LINE V.
WIRING
From Dwg. 21 B801082 Rev. 1
18-GE02D2-4
7